SLVSC97B March   2014  – September 2020 TPS2556-Q1 , TPS2557-Q1

PRODUCTION DATA  

  1. Features
  2. Application
  3. Description
  4. Revision History
  5. Device Comparison Table
  6. Terminal Configuration and Functions
    1.     Terminal Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 Handling Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Typical Characteristics
      1.      16
        1.       Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Overcurrent Conditions
      2. 8.3.2 FAULT Response
      3. 8.3.3 Thermal Sense
    4. 8.4 Device Functional Modes
      1. 8.4.1 Undervoltage Lockout (UVLO)
      2. 8.4.2 Enable ( EN OR EN)
      3. 8.4.3 Auto-Retry Functionality
      4. 8.4.4 Two-Level Current-Limit Circuit
  9. Applications and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application, Design for Current Limit
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Determine Design Parameters
        2. 9.2.2.2 Programming the Current-Limit Threshold
        3. 9.2.2.3 Selecting Current-Limit Resistor 1
        4. 9.2.2.4 Selecting Current-Limit Resistor 2
        5. 9.2.2.5 Accounting for Resistor Tolerance
        6. 9.2.2.6 Power Dissipation and Junction Temperature
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Related Links
    2. 12.2 Trademarks
    3. 12.3 Electrostatic Discharge Caution
    4. 12.4 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range unless otherwise noted(1)(2)
MIN MAX(2) UNIT
Voltage range on IN, OUT, EN or EN, ILIM, FAULT –0.3 7 V
Voltage range from IN to OUT –7 7 V
I Continuous output current Internally limited
Continuous FAULT sink current 25 mA
ILIM source current Internally limited mA
TJ Maximum junction temperature –40 Internally limited °C
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Voltages are referenced to GND unless otherwise noted.