SLVSDJ0E May 2016 – January 2021 TPS25940-Q1
PRODMIX
During start-up into a short circuit current is limited to I(LIM). Figure 9-3 and Figure 10-15 illustrate start-up with a short on the output. This feature helps in quick fault isolation and hence ensures stability of the DC bus.