SLVSDV7C February 2018 – February 2020 TPS2HB16-Q1
PRODUCTION DATA.
In this application, the TPS2HB16-Q1 must allow for the maximum 4.1-A current with margin but minimize the energy in the switch during a fault condition by minimizing the current limit. For this application, the best ILIM set point is approximately 6 A. Equation 7 allows you to calculate the RILIM value that is placed from the ILIMX pins to VBB. RILIM is calculated in kΩ.
Because this device is version A, the KCL value in the Specifications section is 102 A × kΩ.
For a ILIM of 6 A, the RILIM value should be set at approximately 17 kΩ.