4 Revision History
Changes from Revision A (April 2017) to Revision B (July 2021)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
- Removed "±15% Accurate WDT and RST Delays"Go
- Added "Functional Safety-capable" bulletGo
- Updated the Applications to link to the websiteGo
- Added "on the SENSE pin" for clarificationGo
- Updated ESD RatingsGo
- Changed ICWD min and max spec Go
- Changed VCWD min and max spec Go
- Added a footnote to for tINIT
Go
- Created a separate section for Timing DiagramGo
- Added explanation about capacitors for tWDU. Go
- Changed minimum and maximum limits on tWDU from 0.85 and
1.15 to 0.905 and 1.095 respectively Go
- Changed 0.85 to 0.905 in Equation 14 and 1.15 to 1.05 in Equation
15Go
Changes from Revision * (January 2017) to Revision A (April 2017)
- Changed 0.000381 to 0.000324 in Equation 11 Go
- Changed Equation 17 and Equation 18 so that ISENSE is no longer in the denominator Go
- Deleted J row from Device Nomenclature tableGo