SNVSCC2F November 2022 – July 2024 TPS389C03-Q1
PRODUCTION DATA
In the case of power up, AMSK_ON register applies. AMSK_ON masks interrupts until the MON voltage crosses the UVLF threshold or sequence timeout expires whichever is sooner. In the case of power down AMSK_OFF register applies. AMSK_ON masks interrupts until the MON voltage is below the OFF threshold and then the OVLF interrupts are active.
Table 7-2 summarizes the auto-mask operation for power up and power down.
TRANSITION | AUTO-MASK APPLIED | AUTO-MASK APPLIES TO | AUTO-MASK INACTIVE | INTERRUPTS ACTIVE FOR MON CHANNELS NOT IN AUTO-MASK |
---|---|---|---|---|
Power Up |
AMSK_ON |
IEN_UVLF, IEN_UVHF, IEN_OVHF |
SEQ_TOUT expires or rail crosses UVLF | At Power Up |
Power Down |
AMSK_OFF | Auto-mask active in transition until SEQ_TOUT expires | Until SEQ_TOUT expires |