SNVSCC2F November 2022 – July 2024 TPS389C03-Q1
PRODUCTION DATA
TPS389C03-Q1 offers a Open and Close window delay accuracy of ±5%, window delay can be adjusted through register 0xAC and 0xAB respectively. During a reset event, the Open and Close window delays do not change from the programmed value (default OTP or user changes). Table 7-7 lists delay time and associated register value.
Reg Value | Time | Notes |
---|---|---|
0-31 | 1-32ms | 1ms steps |
32-63 | 34-96 ms | 2ms steps |
64-255 | 100-864 ms | 4ms steps |
The startup delay is calculated using the WDT_Startup_DLY_MULTIPLIER[2:0] (register 0xAA), Close window delay, and the Open window delay. It is important to note that changing either the Close window delay or the Open window delay changes the resulting startup delay. Use Equation 3 to calculate total startup delay.