SLUSBO6C JANUARY 2014 – October 2018 TPS40425
PRODUCTION DATA.
Format | Unsigned binary | ||||
Description | The STATUS_ MFR_SPECIFIC command returns one byte containing manufacturer-specific faults or warnings. | ||||
Default | 00000000 (binary) |
read only | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
otfi | x | x | ivaddr | ch1_sps_flt | ch2_sps_flt | ch1_slave | ch2_slave |
Bits | Field Name | Description |
---|---|---|
7 | otfi | (Format: binary)
Over temperature fault internal. This bit is required to distinguish an over temperature fault internal to TPS40425 from an external temperature fault. 0: (Default) The internal temperature is below the fault threshold. 1: The internal temperature is above the fault threshold. |
6:5 | x | Default: 0 |
4 | ivaddr | (Format: binary)
Invalid PMBus address This bit is set when the PMBus address detection circuit does not resolve to a valid address. In this event, the device responds to the address: 127d. 0: (Default) |
3 | ch1_sps_flt | (Format: binary)
Channel 1 smart power-stage fault This bit reports that the smart power-stage has declared a fault (either over-current or over-temperature) on the TSNS1 pin of TPS40425. 0: (Default) |
2 | ch2_sps_flt | (Format: binary)
Channel 2 smart power-stage fault This bit reports that the smart power-stage has declared a fault (either over-current or over-temperature) on the TSNS2 pin of TPS40425. 0: (Default) |
1 | ch1_slave | (Format: binary)
Channel 1 Slave This bit is set when channel 1 is configured as a slave channel (by pulling FB1 > 2.5 V before power-up). It is only used for internal read purposes and does not trigger SMBLERT. 0: (Default) |
0 | ch2_slave | (Format: binary)