SLUSBO6C JANUARY 2014 – October 2018 TPS40425
PRODUCTION DATA.
Format | Unsigned binary | ||||
Description | The STATUS_ TEMPERATURE command returns one byte of information relating to the status of the converter's die temperature related faults.
STATUS_TEMPERATURE is a paged register. In order to access this register for channel 1 of the TPS40425 device, PAGE must be set to 0. In order to access this register for channel 2 of TPS40425 controller, PAGE must be set to 1. For simultaneous access of channels 1 and 2, PAGE command must be set to 11. |
||||
Default | 00000000 (binary) |
PAGE0, PAGE1 | |||||||
read only | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
OTF | OTW | 0 | 0 | 0 | 0 | 0 | 0 |
Bits | Field Name | Description |
---|---|---|
7 | OTF | (= OT Fault in the PMBus Specification)
(Format: binary) Over-Temperature Fault 0: (Default) A temperature fault has not occurred. 1: A temperature fault has occurred. |
6 | OTW | (= OT Warning in the PMBus Specification)
(Format: binary) Over-Temperature Warning 0: (Default) A temperature warning has not occurred. 1: A temperature warning has occurred. |
5:0 | 0 | Default: 0 |