The values of the voltage-divider resistors, RFBH and RFBL determine the output voltage as shown in Figure 38. RFBH is connected between the FB pin and the output, and RFBL is connected between the FB pin and GND. The recommended RFBH value is between 10 kΩ and 20 kΩ. Determine RFBL using Equation 20.
where
In this example R17 has a value of 10-kΩ. R18 is calculated to be 9.91 kΩ. The nearest standard value of 10 kΩ is used for R18.