SLUSB56B November 2012 – April 2019 TPS53819A
PRODUCTION DATA.
Custom register 2 provides software control over mode selection and soft-start time (tSS). The details of each setting are listed in Table 10.
COMMAND | DEFINITION | DESCRIPTION | NVM |
---|---|---|---|
MODE_SOFT_START_CONFIG<7> | — | not supported and don’t care | — |
MODE_SOFT_START_CONFIG<6> | — | not supported and don’t care | — |
MODE_SOFT_START_CONFIG<5> | — | not supported and don’t care | — |
MODE_SOFT_START_CONFIG<4> | — | not supported and don’t care | — |
MODE_SOFT_START_CONFIG<3:2> | SST<1:0> | 00: 1 ms(1)
01: 2 ms 10: 4 ms 11: 8 ms |
Yes |
MODE_SOFT_START_CONFIG<1> | HICLOFF | 0: hiccup after UV(1)
Hiccup interval is (8.96 ms + soft-start time × 7) 1: latch-off after UV |
Yes |
MODE_SOFT_START_CONFIG<0> | CM | 0: DCM(1)
1: FCCM |
Yes |
Figure 34 shows the soft-start timing diagram of TPS53819A with the programmable power-on delay time (tPOD), soft-start time (tSST), and PGOOD delay time (tPGD). During the soft-start time, the controller remains in discontinuous conduction mode (DCM), and then switches to forced continuous conduction mode (FCCM) at the end of soft-start if CM bit (MODE_SOFT_START_CONFIG<0>) is set.