Changes from C Revision (June 2016) to D Revision
- Changed VIN MIN Value From: 4.5 V To: VO + VDO, and added Note 1 in the Recommended Operating ConditionsGo
- Updated text and added Equation 1 in the Low Dropout Operation and Bootstrap Voltage (BOOT) Go
- Deleted text: "The start and stop voltage for a typical 5 V..." and Figure: "5V Start/Stop Voltage" from the Low Dropout Operation and Bootstrap Voltage (BOOT) sectionGo
- Added new section: Minimum VINGo
- Deleted 2 graphs named "Low Dropout Operation" from the Application Curves sectionGo
Changes from B Revision (March 2014) to C Revision
- Changed package HSOIC To: HSOP in the Features and throughout the data sheet Go
- Moved Storage temperature to the Absolute Maximum Ratings table Go
- Changed the Handling Ratings table to the ESD Ratings tableGo
- Changed Output current MAX value From: 5 A To: 3.5 A in the Recommended Operating Conditions tableGo
- Changed Error amplifier transconductance units from µMhos to µS in the Electrical Characteristics tableGo
- Changed Equation 7 and Equation 8Go
- Changed Equation 27Go
Changes from A Revision (February 2013) to B Revision
- Changed the data sheet to the new TI layoutGo
- Changed the Application List From: 12 V, 24 V and 48 V Industrial To: 12 V, 24 V IndustrialGo
- Added the Device Information tableGo
- Added the Handling Ratings tableGo
- Added the Recommended Operating Conditions tableGo
- Added the Thermal Information table inside the document Go
- Changed the Operating: nonswitching supply current TEST CONDITIONS From: FB = 0.83 V To: FB = 0.9 V Go
- Changed RT/CLK high threshold MAX value From: 1.7 V To: 2 V Go
- Changed Figure 6 title From: HIGH FREQUENCY RANGE To: LOW FREQUENCY RANGEGo
- Changed Figure 7 title From: LOW FREQUENCY RANGE To: HIGH FREQUENCY RANGEGo
- Added the Power Supply Recommendations sectionGo
Changes from * Revision (October 2012) to A Revision
- Changed Figure 11 From: IEN (µV) To: IEN (µA)Go
- Changed Figure 12 From: IEN (µV) To: IEN (µA)Go