4 Revision History
Changes from E Revision (June 2016) to F Revision
-
Updated data sheet text to our latest documentation and translations standardsGo
-
Removed all references to the SwitcherPro™ Software Tool because it is no longer available for this partGo
-
Moved storage temperature ratings to the Absolute Maximum Ratings tableGo
-
Changed Handling Ratings table to ESD RatingsGo
-
Changed RHY package to RHL in the Thermal Information tableGo
-
Changed RGY values in the Thermal Information tableGo
-
Updated packages in the last bullet point of Layout GuidelinesGo
-
Added information to the last list item in Layout GuidelinesGo
Changes from D Revision (October 2014) to E Revision
-
Added recommended layout guide lines for sensitive components and the output sensing trace to the Layout Guidelines section.Go
-
Added Receiving Notification of Documentation Updates and Community Resources sections.Go
Changes from C Revision (April 2011) to D Revision
-
Added the Device Information table, Handling Ratings table, the Recommended Operating Conditions table, and the Thermal Information tableGo
-
Changed the Absolute Maximum Ratings for BOOT-PH, MAX value From: 7 V To: 7.7 V Go
-
Changed Equation 28 From: C7(nF) To: C5(nF)Go
Changes from B Revision (October 2010) to C Revision
-
Changed From separate RHL and RGY packages To a combined RHL and RGY packageGo
Changes from A Revision (January 2010) to B Revision
-
Changed Small Signal Model for Frequency Compensation sectionGo
Changes from * Revision (May 2009) to A Revision
-
Changed title from 17 V Input, 6 A Output, Synchronous Step Down Switcher with Integrated FET (SWIFT)Go
-
Changed PowerPAD to Exposed Thermal PadGo
-
Changed Changed the Absolute Maximum Ratings for EN, MAX value From: 3 V To: 6 VGo
-
Changed minimum switching frequency min value from 180 to 160Go
-
Changed minimum switching frequency max value from 220 to 240Go
-
Added "Type 3" block around C11Go
-
Changed PCB Layout graphicGo