SLVSH95 July 2024 TPS546C25
ADVANCE INFORMATION
CMD Address | 9Bh |
Write Transaction: | Block Write |
Read Transaction: | Block Read |
Format: | Unsigned Binary (1 byte) |
NVM Backup: | Yes |
This single byte Block command is used to either set or read the manufacturer’s revision number. It is writeable and includes NVM backup.
Return to Supported PMBus Commands.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RW | RW | RW | RW | RW | RW | RW | RW |
MFR_REVISION |
LEGEND: R/W = Read/Write; R = Read only |