PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
SUPPLY CURRENT | ||||||
IVIN | Operating – non-switching supply current | VIN current, EN = 5 V, VFB = 1 V | 590 | 750 | µA | |
IVINSDN | Shutdown supply current | VIN current, EN = 0 V | 1 | 3 | µA | |
LOGIC THRESHOLD | ||||||
VENH | EN high-level input voltage | EN | 1.35 | 1.6 | V | |
VENL | EN low-level input voltage | EN | 0.9 | 1.05 | V | |
REN | EN pin resistance to GND | VEN = 12 V | 225 | 400 | 900 | kΩ |
VFB VOLTAGE | ||||||
VFBTH | VFB threshold voltage | TA = 25°C | 794 | 806 | 818 | mV |
IFB | VFB input current | VFB = 1 V | 0 | ±0.1 | µA | |
MOSFET | ||||||
RDS(on)h | High-side switch resistance | TA = 25°C, VBST – SW = 5.5 V | 95 | mΩ | ||
RDS(on)l | Low-side switch resistance | TA = 25°C | 57 | mΩ | ||
CURRENT LIMIT | ||||||
Iocl | Low side current limit | Inductor valley current set point. | 3.3 | 4.4 | 5.6 | A |
INocl_l_sink | Low side FET sink current limit | Inductor Negative valley current set point. | 1 | 1.5 | 2 | A |
THERMAL SHUTDOWN | ||||||
TSDN | Thermal shutdown threshold(1) | Shutdown temperature | 172 | °C | ||
Hysteresis | 37 | |||||
ON-TIME TIMER CONTROL | ||||||
tOFF(MIN) | Minimum off time | VFB = 0.5 V | 220 | 310 | ns | |
SOFT START | ||||||
Tss | Soft-start time | Internal soft-start time, test Vout from 10% to 90% | 1.2 | ms | ||
FREQUENCY | ||||||
Fsw | Switching frequency | VO = 1.05 V | 580 | kHz | ||
OUTPUT UNDERVOLTAGE | ||||||
VUVP | Output UVP threshold | Hiccup detect (H > L) | 65% | |||
THICCUP_WAIT | Hiccup on time | 2.2 | ms | |||
THICCUP_RE | Hiccup time before restart | 18.3 | ms | |||
UVLO | ||||||
UVLO | UVLO threshold | Wake up VIN voltage | 4.0 | 4.3 | V | |
Shutdown VIN voltage | 3.3 | 3.6 | ||||
Hysteresis VIN voltage | 0.4 |