SLVSFH6C January 2021 – December 2021 TPS61094
PRODUCTION DATA
In Buck mode operation, the device supports sixteen internally set charging termination voltages by connecting a resistor between the VCHG pin and ground. Table 7-2 lists the termination voltage options with respect to resistance.
RESISTANCE (KΩ) | VCHG_REG (V) | RESISTANCE (KΩ) | VCHG_REG (V) | RESISTANCE (KΩ) | VCHG_REG (V) | RESISTANCE (KΩ) | VCHG_REG (V) |
---|---|---|---|---|---|---|---|
0 | 1.7 | 9.53 | 2.6 | 28.7 | 3.7 | 150 | 4.9 |
3.09 | 2.0 | 13.0 | 2.7 | 49.9 | 4.1 | 205 | 5.0 |
4.75 | 2.2 | 17.4 | 3.6 | 75.0 | 4.15 | 274 | 5.1 |
6.65 | 2.5 | 22.1 | 3.65 | 107 | 4.2 | open | 5.4 |