SLVSH38 November 2023 TPS61377
PRODUCTION DATA
The TPS61377 uses adaptive constant off-time peak current control topology to regulate the output voltage. Under moderate to heavy load conditions, the TPS61377 operates in pulse width modulation (PWM) mode. The switching frequency in PWM mode is 650 kHz (1.2 MHz for TPS613771). At light load, the converter can either operate in PFM mode or in forced PWM mode according to the mode selected.