SLVSEW8B August 2019 – December 2019 TPS66020 , TPS66021
PRODUCTION DATA.
Table 2 summarizes the functional modes for the TPS6602x. As shown, the enabling and disabling of the respective Source or Sink is dependent upon the voltages present on PP5V and VBUS, as well as, the EN0 and EN1 control signals.
EN1 | EN0 | VIN | VVBUS | VPP5V | FLT | Device State | Source Path | Sink Path |
---|---|---|---|---|---|---|---|---|
0 | 0 | ≥ UV_VIN | X | X | Hi-Z | DISABLED | Disabled
Safety engaged. |
Disabled
Safety engaged. |
1 | 0 | ≥ UV_VIN | X | ≥ UV_PP5V | Hi-Z | SRC 1.5 A | Enabled
RCP, OVT, ILIM 1.5-A enabled. |
Disabled
Safety engaged. |
L | SRC FAULT | Disabled
OVP, OVT, ILIMIT, or RCP event. |
Disabled
Safety engaged. |
|||||
< UV_PP5V | L | SRC FAULT | Disabled
PP5V UVLO event. |
Disabled
Safety engaged. |
||||
1 | 1 | ≥ UV_VIN | X | ≥ UV_PP5V | Hi-Z | SRC 3 A | Enabled
RCP, OVT, ILIM 3-A enabled. |
Disabled
Safety engaged. |
L | SRC FAULT | Disabled
OVP, OVT, ILIMIT, or RCP event. |
Disabled
Safety engaged. |
|||||
< UV_PP5V | L | SRC FAULT | Disabled
PP5V UVLO event. |
Disabled
Safety engaged. |
||||
0 | 1 | ≥ UV_VIN | ≥ UV_VBUS | X | Hi-Z | SNK | Disabled
Safety engaged. |
Enabled
RCP, OVT enabled |
X | Hi-Z | SNK FAULT | Disabled
Safety engaged. |
Enabled with Blocking
RCP event. |
||||
X | L | SNK FAULT | Disabled
Safety engaged. |
Disabled
OVP(2) or OVT event. |
||||
< UV_VBUS | X | Hi-Z | SNK FAULT | Disabled
Safety engaged. |
Disabled
VBUS UVLO event. |
|||
1 | 1 | ≥ UV_VIN | ≥ vSafe5V | ≥ UV_PP5V | Hi-Z | FRS | Disabled
OVT, ILIM 3-A enabled |
Disabled
Safety engaged. |
< vSafe5V | ≥ UV_PP5V | Hi-Z | SRC 3 A | Enabled
RCP, OVT, ILIM 3-A enabled |
Disabled
Safety engaged. |
|||
≥ UV_PP5V | L | SRC FAULT | Disabled
OVP, OVT, ILIMIT, or RCP event. |
Disabled
Safety engaged. |
||||
< UV_PP5V | L | SRC FAULT | Disabled
PP5V UVLO event. |
Disabled
Safety engaged. |
||||
X | X | < UV_VIN | < UV_VBUS | X | Hi-Z | DISABLED | Disabled
Safety engaged. |
Disabled
Safety engaged. |
0 | 0 | < UV_VIN | ≥ UV_VBUS | X | Hi-Z | DISABLED | Disabled
Safety engaged. |
Disabled
Safety engaged. |
1 | 0 | < UV_VIN | ≥ UV_VBUS | ≥ UV_PP5V | L | SRC FAULT | Disabled
RCP, OVT, ILIM 1.5A enabled |
Disabled
Safety engaged. |
1 | 1 | < UV_VIN | ≥ UV_VBUS | ≥ UV_PP5V | L | SRC FAULT | Disabled
RCP, OVT, ILIM 3A enabled |
Disabled
Safety engaged. |
0 | 1 | < UV_VIN | ≥ UV_VBUS(3) | X | Hi-Z | SNK | Disabled
Safety engaged. |
Enabled
RCP, OVT enabled |
X | Hi-Z | SNK FAULT | Disabled
Safety engaged. |
Enabled with Blocking
RCP event. |
||||
X | L | SNK FAULT | Disabled
Safety engaged. |
Disabled
OVP(2) or OVT event. |
||||
< UV_VBUS(3) | X | Hi-Z | SNK FAULT | Disabled
Safety engaged. |
Disabled
VBUS UVLO event. |