SLUSEG1A August 2021 – December 2021 TPS92519-Q1
PRODUCTION DATA
The TPS92519-Q1 has an enable input EN for start-up and shutdown control of the output. If the enable input is greater than 1.8 V then both channels are enabled. If the enable pin is pulled below 0.8 V, the channels are disabled and the TPS92519-Q1 is switched to a low IQ shutdown mode. In this mode, the device draws a 2-μA typical current from the VIN pin and 17-μA typical from V5D pin. TI does not recommend leaving EN pin floating.