SLUSCX8C March 2019 – March 2021 TPS92682-Q1
PRODUCTION DATA
The output Overvoltage level is programmed using a resistor divider, RFB2 and RFB1, from the output voltage, VO, to GND. RFB2 can be calculated from the VOV(HYS) = 2.4 V and Equation 37:
RFB2 = 120 kΩ
RFB1 can be calculated from Equation 35 and the required value of VO(OV) = 50 V:
RFB1 = 3 kΩ