SLUSCX8C March 2019 – March 2021 TPS92682-Q1
PRODUCTION DATA
As shown in Figure 7-8, an internal switch pulls down the COMPx pin when there is a fault. The Comp-Pull-Down discharges the compensator capacitors, such that the converter start-up always begins from a known state.
The converter does not start unless the COMPx voltage decreases below 100 mV (when CHx_complow goes high).