SLVSDT1C July 2017 – June 2020 TPSM82480
PRODUCTION DATA.
When the load current is below the internal threshold, only the master phase operates. The second phase activates, if the load current exceeds the threshold of typically 1.7 A. The second phase powers off with a hysteresis of approxiimately 0.5 A, when the load current decreases.