SLUSDC9A August   2018  – June 2021 TPSM831D31

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  References: DAC
    7. 6.7  Telemetry
    8. 6.8  Current Sense and Calibration
    9. 6.9  Logic Interface Pins: A_EN, A_PGOOD, B_EN, B_PGOOD,RESET
    10. 6.10 Protections: OVP and UVP
    11. 6.11 Typical Characteristics (VIN = 12 V)
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 DCAP+ Control
      2. 7.3.2 Setting the Load-Line (DROOP)
      3. 7.3.3 Start-Up Timing
      4. 7.3.4 Load Transitions
      5. 7.3.5 Switching Frequency
      6. 7.3.6 RESET Function
      7. 7.3.7 VID Table
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous Conduction Mode
      2. 7.4.2 Operation With EN Signal Control
      3. 7.4.3 Operation With OPERATION Control
      4. 7.4.4 Operation With EN and OPERATION Control
    5. 7.5 Programming
      1. 7.5.1  PMBus Connections
      2. 7.5.2  PMBus Address Selection
      3. 7.5.3  Supported Commands
      4. 7.5.4  Commonly Used PMBus Commands
      5. 7.5.5  Voltage, Current, Power, and Temperature Readings
        1. 7.5.5.1 (88h) READ_VIN
        2. 7.5.5.2 (89h) READ_IIN
        3. 7.5.5.3 (8Bh) READ_VOUT
        4. 7.5.5.4 (8Ch) READ_IOUT
        5. 7.5.5.5 (8Dh) READ_TEMPERATURE_1
        6. 7.5.5.6 (96h) READ_POUT
        7. 7.5.5.7 (97h) READ_PIN
        8. 7.5.5.8 (D4h) MFR_SPECIFIC_04
      6. 7.5.6  Output Current Sense and Calibration
        1. 7.5.6.1 Reading Individual Phase Currents
          1. 7.5.6.1.1 Reading Total Current
          2. 7.5.6.1.2 51
      7. 7.5.7  Output Voltage Margin Testing
        1. 7.5.7.1 (01h) OPERATION
        2. 7.5.7.2 (26h) VOUT_MARGIN_LOW
        3. 7.5.7.3 (25h) VOUT_MARGIN_HIGH
      8. 7.5.8  Loop Compensation
        1. 7.5.8.1 (D7h) MFR_SPECIFIC_07
        2. 7.5.8.2 (28h) VOUT_DROOP
      9. 7.5.9  Converter Protection and Response
      10. 7.5.10 Output Overvoltage Protection and Response
        1. 7.5.10.1 (40h) VOUT_OV_FAULT_LIMIT
        2. 7.5.10.2 (41h) VOUT_OV_FAULT_RESPONSE
      11. 7.5.11 Maximum Allowed Output Voltage Setting
        1. 7.5.11.1 (24h) VOUT_MAX
      12. 7.5.12 Output Undervoltage Protection and Response
        1. 7.5.12.1 (44h) VOUT_UV_FAULT_LIMIT
        2. 7.5.12.2 (45h) VOUT_UV_FAULT_RESPONSE
      13. 7.5.13 Minimum Allowed Output Voltage Setting
        1. 7.5.13.1 (2Bh) VOUT_MIN
      14. 7.5.14 Output Overcurrent Protection and Response
        1. 7.5.14.1 (46h) IOUT_OC_FAULT_LIMIT
        2. 7.5.14.2 (4Ah) IOUT_OC_WARN_LIMIT
        3. 7.5.14.3 (47h) IOUT_OC_FAULT_RESPONSE
        4. 7.5.14.4 Per Phase Overcurrent Limit Thresholds
      15. 7.5.15 Input Under-Voltage Lockout (UVLO)
        1. 7.5.15.1 (35h) VIN_ON
      16. 7.5.16 Input Over-Voltage Protection and Response
        1. 7.5.16.1 (55h) VIN_OV_FAULT_LIMIT
        2. 7.5.16.2 (56h) VIN_OV_FAULT_RESPONSE
      17. 7.5.17 Input Undervoltage Protection and Response
        1. 7.5.17.1 (59h) VIN_UV_FAULT_LIMIT
        2. 7.5.17.2 (5Ah) VIN_UV_FAULT_RESPONSE
      18. 7.5.18 Input Overcurrent Protection and Response
        1. 7.5.18.1 (5Bh) IIN_OC_FAULT_LIMIT
        2. 7.5.18.2 (5Dh) IIN_OC_WARN_LIMIT
        3. 7.5.18.3 (5Ch) IIN_OC_FAULT_RESPONSE
      19. 7.5.19 Overtemperature Protection and Response
        1. 7.5.19.1 (4Fh) OT_FAULT_LIMIT
        2. 7.5.19.2 (51h) OT_WARN_LIMIT
        3. 7.5.19.3 (50h) OT_FAULT_RESPONSE
      20. 7.5.20 Dynamic Phase Shedding (DPS)
        1. 7.5.20.1 (DEh) MFR_SPECIFIC_14
        2. 7.5.20.2 (DFh) MFR_SPECIFIC_15
      21. 7.5.21 NVM Programming
      22. 7.5.22 NVM Security
        1. 7.5.22.1 (FAh) MFR_SPECIFIC_42
      23. 7.5.23 Black Box Recording
        1. 7.5.23.1 (D8h) MFR_SPECIFIC_08
      24. 7.5.24 Board Identification and Inventory Tracking
      25. 7.5.25 Status Reporting
        1. 7.5.25.1 (78h) STATUS_BYTE
        2. 7.5.25.2 (79h) STATUS_WORD
        3. 7.5.25.3 (7Ah) STATUS_VOUT
        4. 7.5.25.4 (7Bh) STATUS_IOUT
        5. 7.5.25.5 (7Ch) STATUS_INPUT
        6. 7.5.25.6 (7Dh) STATUS_TEMPERATURE
        7. 7.5.25.7 (7Eh) STATUS_CML
        8. 7.5.25.8 (80h) STATUS_MFR_SPECIFIC
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Input Capacitors
        2. 8.2.2.2 Output Capacitors
        3. 8.2.2.3 Switching Frequency
        4. 8.2.2.4 Set PMBus Address
        5. 8.2.2.5 PMBus GUI Default Values
      3. 8.2.3 Application Performance Plots
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Examples
  11. 11Device and Documentation Support
    1. 11.1 Receiving Notification of Documentation Updates
    2. 11.2 Support Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
  • MOA|28
Thermal pad, mechanical data (Package|Pins)
Orderable Information

(5Dh) IIN_OC_WARN_LIMIT

The IIN_OC_WARN_LIMIT command sets the value of the input current, in amperes, that causes the input overcurrent warning condition. The IIN_OC_WARN_LIMIT command must be accessed through Read Word/Write Word transactions. The IIN_OC_WARN_LIMIT command is shared between Channel A and Channel B. All transactions to this command will affect both channels regardless of the PAGE command.

Upon triggering the over-current warning, the device:

  • sets the OTHER bit in the STATUS_BYTE
  • sets the INPUT bit in the STATUS_WORD
  • sets the IIN_Over-current Warning bit in the STATUS_INPUT register, and
  • notifies the host (asserts PMB_ALERT, if the corresponding mask bit in SMBALERT_MASK is not set)
IIN_OC_WARN_LIMIT
15141312111098
RRRRRRRR
IIN_OCW_EXPIIN_OCW_MAN
76543210
RRWRWRWRWRWRWRW
IIN_OCW_MAN
LEGEND: R/W = Read/Write; R = Read only
Table 7-49 IIN_OC_FAULT_LIMIT Register Field Descriptions
BitFieldTypeResetDescription
15:11IIN_OCW_EXPR11111bLinear two's complement format exponent, –1. LSB = 0.5 A.
10:0IIN_OCW_MANRWSee below.Linear two's complement format mantissa. Acceptable values range from 0d (0 A) to 127d (63.5 A).

During operation, the IIN_OC_FAULT_LIMIT may be changed to any valid value, as specified above. The IIN_OC_FAULT_LIMIT command has only limited NVM backup. The table below summarizes the values that IIN_OC_FAULT_LIMIT may be restored to following a reset, or RESTORE_DEFAULT_ALL operation.

Table 7-50 IIN_OC_WARN_LIMIT reset values
Hex ValueIIN_OC_WARN_LIMIT during
NVM store operation
IIN_OC_WARN_LIMIT following
Reset/Restore Operation
F810h8 A8 A
F820h16 A16 A
F830h24 A24 A
F840h32 A32 A
F850h40 A40 A
F860h48 A48 A
F870h56 A56 A
F87Fh63.5 A63.5 A
Any other valid dataAny other valid data63.5 A