SLUSDC9A August   2018  – June 2021 TPSM831D31

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  References: DAC
    7. 6.7  Telemetry
    8. 6.8  Current Sense and Calibration
    9. 6.9  Logic Interface Pins: A_EN, A_PGOOD, B_EN, B_PGOOD,RESET
    10. 6.10 Protections: OVP and UVP
    11. 6.11 Typical Characteristics (VIN = 12 V)
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 DCAP+ Control
      2. 7.3.2 Setting the Load-Line (DROOP)
      3. 7.3.3 Start-Up Timing
      4. 7.3.4 Load Transitions
      5. 7.3.5 Switching Frequency
      6. 7.3.6 RESET Function
      7. 7.3.7 VID Table
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous Conduction Mode
      2. 7.4.2 Operation With EN Signal Control
      3. 7.4.3 Operation With OPERATION Control
      4. 7.4.4 Operation With EN and OPERATION Control
    5. 7.5 Programming
      1. 7.5.1  PMBus Connections
      2. 7.5.2  PMBus Address Selection
      3. 7.5.3  Supported Commands
      4. 7.5.4  Commonly Used PMBus Commands
      5. 7.5.5  Voltage, Current, Power, and Temperature Readings
        1. 7.5.5.1 (88h) READ_VIN
        2. 7.5.5.2 (89h) READ_IIN
        3. 7.5.5.3 (8Bh) READ_VOUT
        4. 7.5.5.4 (8Ch) READ_IOUT
        5. 7.5.5.5 (8Dh) READ_TEMPERATURE_1
        6. 7.5.5.6 (96h) READ_POUT
        7. 7.5.5.7 (97h) READ_PIN
        8. 7.5.5.8 (D4h) MFR_SPECIFIC_04
      6. 7.5.6  Output Current Sense and Calibration
        1. 7.5.6.1 Reading Individual Phase Currents
          1. 7.5.6.1.1 Reading Total Current
          2. 7.5.6.1.2 51
      7. 7.5.7  Output Voltage Margin Testing
        1. 7.5.7.1 (01h) OPERATION
        2. 7.5.7.2 (26h) VOUT_MARGIN_LOW
        3. 7.5.7.3 (25h) VOUT_MARGIN_HIGH
      8. 7.5.8  Loop Compensation
        1. 7.5.8.1 (D7h) MFR_SPECIFIC_07
        2. 7.5.8.2 (28h) VOUT_DROOP
      9. 7.5.9  Converter Protection and Response
      10. 7.5.10 Output Overvoltage Protection and Response
        1. 7.5.10.1 (40h) VOUT_OV_FAULT_LIMIT
        2. 7.5.10.2 (41h) VOUT_OV_FAULT_RESPONSE
      11. 7.5.11 Maximum Allowed Output Voltage Setting
        1. 7.5.11.1 (24h) VOUT_MAX
      12. 7.5.12 Output Undervoltage Protection and Response
        1. 7.5.12.1 (44h) VOUT_UV_FAULT_LIMIT
        2. 7.5.12.2 (45h) VOUT_UV_FAULT_RESPONSE
      13. 7.5.13 Minimum Allowed Output Voltage Setting
        1. 7.5.13.1 (2Bh) VOUT_MIN
      14. 7.5.14 Output Overcurrent Protection and Response
        1. 7.5.14.1 (46h) IOUT_OC_FAULT_LIMIT
        2. 7.5.14.2 (4Ah) IOUT_OC_WARN_LIMIT
        3. 7.5.14.3 (47h) IOUT_OC_FAULT_RESPONSE
        4. 7.5.14.4 Per Phase Overcurrent Limit Thresholds
      15. 7.5.15 Input Under-Voltage Lockout (UVLO)
        1. 7.5.15.1 (35h) VIN_ON
      16. 7.5.16 Input Over-Voltage Protection and Response
        1. 7.5.16.1 (55h) VIN_OV_FAULT_LIMIT
        2. 7.5.16.2 (56h) VIN_OV_FAULT_RESPONSE
      17. 7.5.17 Input Undervoltage Protection and Response
        1. 7.5.17.1 (59h) VIN_UV_FAULT_LIMIT
        2. 7.5.17.2 (5Ah) VIN_UV_FAULT_RESPONSE
      18. 7.5.18 Input Overcurrent Protection and Response
        1. 7.5.18.1 (5Bh) IIN_OC_FAULT_LIMIT
        2. 7.5.18.2 (5Dh) IIN_OC_WARN_LIMIT
        3. 7.5.18.3 (5Ch) IIN_OC_FAULT_RESPONSE
      19. 7.5.19 Overtemperature Protection and Response
        1. 7.5.19.1 (4Fh) OT_FAULT_LIMIT
        2. 7.5.19.2 (51h) OT_WARN_LIMIT
        3. 7.5.19.3 (50h) OT_FAULT_RESPONSE
      20. 7.5.20 Dynamic Phase Shedding (DPS)
        1. 7.5.20.1 (DEh) MFR_SPECIFIC_14
        2. 7.5.20.2 (DFh) MFR_SPECIFIC_15
      21. 7.5.21 NVM Programming
      22. 7.5.22 NVM Security
        1. 7.5.22.1 (FAh) MFR_SPECIFIC_42
      23. 7.5.23 Black Box Recording
        1. 7.5.23.1 (D8h) MFR_SPECIFIC_08
      24. 7.5.24 Board Identification and Inventory Tracking
      25. 7.5.25 Status Reporting
        1. 7.5.25.1 (78h) STATUS_BYTE
        2. 7.5.25.2 (79h) STATUS_WORD
        3. 7.5.25.3 (7Ah) STATUS_VOUT
        4. 7.5.25.4 (7Bh) STATUS_IOUT
        5. 7.5.25.5 (7Ch) STATUS_INPUT
        6. 7.5.25.6 (7Dh) STATUS_TEMPERATURE
        7. 7.5.25.7 (7Eh) STATUS_CML
        8. 7.5.25.8 (80h) STATUS_MFR_SPECIFIC
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Input Capacitors
        2. 8.2.2.2 Output Capacitors
        3. 8.2.2.3 Switching Frequency
        4. 8.2.2.4 Set PMBus Address
        5. 8.2.2.5 PMBus GUI Default Values
      3. 8.2.3 Application Performance Plots
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Examples
  11. 11Device and Documentation Support
    1. 11.1 Receiving Notification of Documentation Updates
    2. 11.2 Support Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
  • MOA|28
Thermal pad, mechanical data (Package|Pins)
Orderable Information

(7Eh) STATUS_CML

The STATUS_CML command returns one byte with contents regarding communication, logic, or memory conditions.

The STATUS_CML command must be accessed through Read Byte/Write Byte transactions. The STATUS_CML command is shared between Channel A and Channel B. All transactions to this command affects both channels regardless of the PAGE command.

Figure 7-10 STATUS_CML Register
76543210
RWRWRWRW00RW0
IV_CMDIV_DATAPEC_FAILMEMPRO_FAULTReservedCOM_FAILCML_OTHER
Table 7-68 STATUS_CML Register Field Descriptions
BitFieldTypeResetDescription
7IV_CMDRWCurrent
Status
Invalid or Unsupported Command Received
0: Latched flag indicating no invalid or unsupported command has been received.
1: Latched flag indicating an invalid or unsupported command has been received.
6IV_DATARWCurrent
Status
Invalid or Unsupported Data Received
0: Latched flag indicating no invalid or unsupported data has been received.
1: Latched flag indicating an invalid or unsupported data has been received.
5PEC_FAILRWCurrent
Status
Packet Error Check Failed
0: Latched flag indicating no packet error check has failed
1: Latched flag indicating a packet error check has failed
4ReservedR0Always set to 0.
3MEMRWCurrent
Status
Memory/NVM Error
0: Latched flag indicating no memory error has occurred
1: Latched flag indicating a memory error has occurred
2ReservedR0Always set to 0.
1COM_FAILRWCurrent
Status
Other Communication Faults
0: Latched flag indicating no communication fault other than the ones listed in this table has occurred.
1: Latched flag indicating a communication fault other than the ones listed in this table has occurred.
0CML_OTHERR0Not supported and always set to 0.

Per the description in the PMBus 1.3 specification, part II, TPSM831D31 does support clearing of status bits by writing to STATUS registers. Writing a 1 to any bit in this register attempts to clear it as a fault condition.