SCDS186E FEBRUARY   2005  – February 2018 TS5A3166

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Simplified Schematic
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics for 5-V Supply
    6. 6.6 Electrical Characteristics for 3.3-V Supply
    7. 6.7 Electrical Characteristics for 2.5-V Supply
    8. 6.8 Electrical Characteristics for 1.8-V Supply
    9. 6.9 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Device Support
      1. 12.1.1 Device Nomenclature
    2. 12.2 Community Resources
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics for 2.5-V Supply

V+ = 2.3 V to 2.7 V, TA = –40°C to 85°C (unless otherwise noted)(1)
PARAMETERTEST CONDITIONSTAV+MINTYPMAXUNIT
Analog Switch
VCOM,
VNO
Analog signal range 2.3 V 0 V+ V
rpeak Peak ON resistance 0 ≤ VNO ≤ V+,
ICOM = –100 mA,
Switch ON,
see Figure 13
25°C 2.3 V 1.8 2.4 Ω
Full 2.6
ron ON-state resistance VNO = 2 V,
ICOM = –100 mA,
Switch ON,
see Figure 13
25°C 2.3 V 1.2 2.1 Ω
Full 2.4
ron(flat) ON-state resistance
flatness
0 ≤ VNO ≤ V+,
ICOM = –100 mA,
Switch ON,
see Figure 13
25°C 2.3 V 0.7 Ω
VNO = 2 V, 0.8 V,
ICOM = –100 mA,
25°C 0.4 0.6
Full 0.6
INO(OFF) NO
OFF leakage current
VNO = 1 V,
VCOM = 3 V,
or
VNO = 3 V,
VCOM = 1 V,
Switch OFF,
see Figure 14
25°C 2.7 V –5 0.3 5 nA
Full –50 50
INO(PWROFF) VNO = 0 to 3.6 V,
VCOM = 3.6 V to 0,
25°C 0 V –2 0.05 2 μA
Full –15 15
ICOM(OFF) COM
OFF leakage current
VCOM = 1 V,
VNO = 3 V,
or
VCOM = 3 V,
VNO = 1 V,
Switch OFF,
see Figure 14
25°C 2.7 V –5 0.3 5 nA
Full –50 50
ICOM(PWROFF) VCOM = 3.6 V to 0,
VNO = 0 to 3.6 V,
25°C 0 V –2 0.05 2 μA
Full –15 15
INO(ON) NO
ON leakage current
VNO = 1 V,
VCOM = Open,
or
VNO = 3 V,
VCOM = Open,
Switch ON,
see Figure 15
25°C 2.7 V –2 0.3 2 nA
Full –20 20
ICOM(ON) COM
ON leakage current
VCOM = 1 V,
VNO = Open,
or
VCOM = 3 V,
VNO = Open,
Switch ON,
see Figure 15
25°C 2.7 V –2 0.3 2 nA
Full –20 20
Digital Control Inputs (IN1, IN2)
VIH Input logic high Full 1.8 5.5 V
VIL Input logic low Full 0 0.6 V
IIH, IIL Input leakage current VI = 5.5 V or 0 25°C 2.7 V –2 0.3 2 nA
Full –20 20
Dynamic
tON Turnon time VCOM = V+,
RL = 50 Ω,
CL = 35 pF,
see Figure 17
25°C 2.5 V 2 6 10 ns
Full 2.3 V to 2.7 V 1 12
tOFF Turnoff time VCOM = V+,
RL = 50 Ω,
CL = 35 pF,
see Figure 17
25°C 2.5 V 4.5 8 10.5 ns
Full 2.3 V to 2.7 V 3 15
QC Charge injection VGEN = 0,
RGEN = 0,
CL = 1 nF,
see Figure 21
25°C 2.5 V 4 pC
CNO(OFF) NO
OFF capacitance
VNO = V+ or GND,
Switch OFF,
See Figure 16 25°C 2.5 V 19.5 pF
CCOM(OFF) COM
OFF capacitance
VCOM = V+ or GND,
Switch OFF,
See Figure 16 25°C 2.5 V 18.5 pF
CNO(ON) NO
ON capacitance
VNO = V+ or GND,
Switch ON,
See Figure 16 25°C 2.5 V 36.5 pF
CCOM(ON) COM
ON capacitance
VCOM = V+ or GND,
Switch ON,
See Figure 16 25°C 2.5 V 36.5 pF
CI Digital input
capacitance
VI = V+ or GND, See Figure 16 25°C 2.5 V 2 pF
BW Bandwidth RL = 50 Ω,
Switch ON,
See Figure 18 25°C 2.5 V 150 MHz
OISO OFF isolation RL = 50 Ω,
f = 1 MHz,
Switch OFF,
see Figure 19
25°C 2.5 V –62 dB
THD Total harmonic
distortion
RL = 600 Ω,
CL = 50 pF,
f = 20 Hz to 20 kHz,
see Figure 21
25°C 2.5 V 0.02%
Supply
I+ Positive supply
current
VI = V+ or GND, Switch ON or OFF 25°C 2.7 V 0.001 0.02 μA
Full 0.25
The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum.