SLLSF89A September 2018 – December 2018 TUSB217-Q1
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
TUSB217-Q1 can be disabled when its RSTN pin is asserted low. DP, DM traces are continuous through the device in shutdown mode. The USB channel is still fully operational, but there is neither signal compensation, nor any indication from the CD pin as to the status of the channel.
MODE | CD | ENA_HS |
---|---|---|
Low speed | HIGH | LOW |
Full speed | HIGH | LOW |
High speed | HIGH | HIGH |
High speed downstream port electrical test | LOW | HIGH |
Shutdown | LOW | LOW |