SLLSEE5D february   2013  – july 2023 TUSB8040A1

PRODUCTION DATA  

  1.   1
  2. 1Features
  3. 2Applications
  4. 3Description
  5. 4Revision History
  6. 5Pin Configuration and Functions
  7. 6Specifications
    1. 6.1 Absolute Maximum Ratings #GUID-9FC00080-214A-41B8-A47D-B9F7BA87DE22/SLLSE42922
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 3.3-V I/O Electrical Characteristics
    6. 6.6 Hub Input Supply Current
    7. 6.7 Timing and Switching Characteristics
      1. 6.7.1 Clock Generation
      2. 6.7.2 Crystal Requirements
      3. 6.7.3 Input Clock Requirements
  8. 7Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Memory
    4. 7.4 I2C EEPROM Operation
    5. 7.5 SMBus Target Operation
    6. 7.6 Configuration Registers
      1. 7.6.1  ROM Signature Register
      2. 7.6.2  Vendor ID LSB Register
      3. 7.6.3  Vendor ID MSB Register
      4. 7.6.4  Product ID LSB Register
      5. 7.6.5  Product ID MSB Register
      6. 7.6.6  Device Configuration Register
      7. 7.6.7  Battery Charging Support Register
      8. 7.6.8  Device Removable Configuration Register
      9. 7.6.9  Port Used Configuration Register
      10. 7.6.10 Reserved Register
      11. 7.6.11 Reserved Register
      12. 7.6.12 Language ID LSB Register
      13. 7.6.13 Language ID MSB Register
      14. 7.6.14 Serial Number String Length Register
      15. 7.6.15 Manufacturer String Length Register
      16. 7.6.16 Product String Length Register
      17. 7.6.17 Reserved Register
      18. 7.6.18 Serial Number Registers
      19. 7.6.19 Manufacturer String Registers
      20. 7.6.20 Product String Registers
      21. 7.6.21 Additional Feature Configuration Register
      22. 7.6.22 Reserved Register
      23. 7.6.23 Reserved Register
      24. 7.6.24 Device Status and Command Register
  9. 8Applications, Implementation, and Layout
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Upstream Port Implementation
        2. 8.2.2.2 Downstream Port 1 Implementation
        3. 8.2.2.3 Downstream Port 2 Implementation
        4. 8.2.2.4 Downstream Port 3 Implementation
        5. 8.2.2.5 Downstream Port 4 Implementation
        6. 8.2.2.6 VBUS Power Switch Implementation
        7. 8.2.2.7 Clock, Reset, I2C/SMBUS, and Misc
        8. 8.2.2.8 Power Implementation
      3. 8.2.3 Application Curve
      4. 8.2.4 Power Supply Recommendations
        1. 8.2.4.1 Power Up and Reset
      5. 8.2.5 Layout
        1. 8.2.5.1 Layout Guidelines
          1. 8.2.5.1.1 Part Placement
          2. 8.2.5.1.2 Board Layout Considerations
            1. 8.2.5.1.2.1  RKM Package – QFN (Quad Flat No-Lead)
            2. 8.2.5.1.2.2  Impedance
            3. 8.2.5.1.2.3  Critical Signals
            4. 8.2.5.1.2.4  Crystal
            5. 8.2.5.1.2.5  USB Interface
            6. 8.2.5.1.2.6  Differential Pair Signals
              1. 8.2.5.1.2.6.1 Internal Bond Wire Mismatch
            7. 8.2.5.1.2.7  Port Connectors
            8. 8.2.5.1.2.8  Reset Terminals
            9. 8.2.5.1.2.9  Miscellaneous Terminals
            10. 8.2.5.1.2.10 Power Control and Battery Charging Terminals
            11. 8.2.5.1.2.11 USB 2.0 Port Indicator LED Terminals
          3. 8.2.5.1.3 Power
            1. 8.2.5.1.3.1 Power
            2. 8.2.5.1.3.2 Downstream Port Power
            3. 8.2.5.1.3.3 Ground
        2. 8.2.5.2 Layout Example
  10. 9Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11.   Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Overview

The TUSB8040A1 supports per port or ganged power switching and over-current protection.

An individually port power controlled hub switches power on or off to each downstream port as requested by the USB host. Also when an individually port power controlled hub senses an over-current event, only power to the affected downstream port will be switched off.

A ganged hub switches on power to all its downstream ports when power is required to be on for any port. The power to the downstream ports is not switched off unless all ports are in a state that allows power to be removed. Also when a ganged hub senses an over-current event, power to all downstream ports will be switched off.

The TUSB8040A1 also provides customization using an I2C EEPROM or configuration via an SMBus host for vendor specific PID, VID, and strings. For the TUSB8040A1 ports can also be marked as disabled or permanently attached using pin selection, I2C EEPROM or an SMBus host. The Device Status and Command Register at F8h cannot be modified by the contents of the I2C EEPROM.