SLUSCU6C August 2017 – January 2020 UCC256301
PRODUCTION DATA.
First, determine the transformer turns ratio by the nominal input and output voltages.
Then determine the LLC gain range Mg(min) and Mg(max). Assume there is a 0.5-V drop in the rectifier diodes (Vf) and a further 0.5-V drop due to other losses (Vloss).