SLUSCU6C August 2017 – January 2020 UCC256301
PRODUCTION DATA.
The AC voltage across the resonant inductor is given by its impedance times the current:
The inductor can be built or purchased according to the following specifications:
The minimum operating frequency during normal operation is that calculated above but during shutdown the LLC can operate at right above ZCS boundary condition, which is a lower frequency. The magnetic components in the resonant circuit, the transformer and resonant inductor, should be rated to operate at this lower frequency.