7.3.14.2 Over Current Protection (OCP)
There are three levels of OCP:
- OCP1: peak current protection (highest threshold)
- Fault action: count OCP1 cycles and shut down power stage if counter exceeds preset value
- OCP2: average input current protection (high threshold)
- Fault action: if above threshold for 2 ms, shut down
- OCP3: average input current protection (low threshold)
- Fault action: if above threshold for 50 ms, shut down
The circuit block diagram has been discussed in the Resonant Current Sensing section.