SLUSDX3C
november 2020 – august 2023
UCC25800-Q1
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Revision History
5
Device Comparison Table
6
Pin Configuration and Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Power Management
8.3.2
Oscillator
8.3.3
External Synchronization
8.3.4
Dead-Time
8.3.4.1
Adaptive Dead-time
8.3.4.2
Maximum Programmable Dead-time
8.3.5
Protections
8.3.5.1
Overcurrent Protection
8.3.5.1.1
OCP Threshold Setting
8.3.5.1.2
Output Power Capability
8.3.5.2
Input Overvoltage Protection (OVP)
8.3.5.3
Over-Temperature Protection (TSD)
8.3.5.4
Pin-Fault Protections
8.3.5.5
VREG Pin Protection
8.3.6
DIS/FLT Pin operation
8.3.6.1
FAULT Codes
8.4
Device Functional Modes
8.4.1
UVLO Mode
8.4.2
Soft-start Mode
8.4.3
Normal Operation Mode
8.4.4
Disabled Mode
8.4.5
Fault Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
LLC Converter Operation Principle
9.2.2
Design Requirements
9.2.3
Detailed Design Procedure
9.2.4
Application Curves
9.3
What to Do and What Not to Do
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.2
Layout Example
12
Device and Documentation Support
12.1
Documentation Support
12.1.1
Related Documentation
12.2
Receiving Notification of Documentation Updates
12.3
Support Resources
12.4
Trademarks
12.5
Electrostatic Discharge Caution
12.6
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DGN|8
MPDS046G
Thermal pad, mechanical data (Package|Pins)
DGN|8
PPTD362A
Orderable Information
slusdx3c_oa
slusdx3c_pm
1
Features
High-efficiency half-bridge transformer driver
Ultra-low EMI with low interwinding capacitance
Smaller and lower-cost transformer
Programmable frequency: 0.1 MHz to 1.2 MHz
Wide input voltage range: 9 V to 34 V
9 W from 34-V input
6 W from 24-V input
4 W from 15-V input
Automatic dead-time adjustment with maximum dead-time programming
External clock synchronization for low noise
Robust protection features
Undervoltage lockout (UVLO)
Programmable over-current protection (OCP)
Input overvoltage protection (OVP)
Over temperature protection (TSD)
Integrated soft-start to reduce in-rush current
External disable function with fault-code output
AEC-Q100 qualified for automotive applications:
Temperature grade 1: –40°C to +125°C, T
A
Functional Safety-Capable
Documentation
available to aid functional safety system design
8-Pin DGN package with thermal pad