SLUSE44D
April 2020 – May 2024
UCC27624
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Switching Characteristics
5.7
Timing Diagrams
5.8
Typical Characteristics
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
Operating Supply Current
6.3.2
Input Stage
6.3.3
Enable Function
6.3.4
Output Stage
6.3.5
Low Propagation Delays and Tightly Matched Outputs
6.4
Device Functional Modes
7
Application and Implementation
7.1
Application Information
7.2
Typical Application
7.2.1
Design Requirements
7.2.2
Detailed Design Procedure
7.2.2.1
VDD and Undervoltage Lockout
7.2.2.2
Drive Current and Power Dissipation
7.2.3
Application Curves
8
Power Supply Recommendations
9
Layout
9.1
Layout Guidelines
9.2
Layout Example
9.3
Thermal Considerations
10
Device and Documentation Support
10.1
Device Support
10.1.1
Third-Party Products Disclaimer
10.2
Receiving Notification of Documentation Updates
10.3
Support Resources
10.4
Trademarks
10.5
Electrostatic Discharge Caution
10.6
Glossary
11
Revision History
12
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
D|8
MSOI002K
DGN|8
MPDS046G
Thermal pad, mechanical data (Package|Pins)
DGN|8
PPTD388A
Orderable Information
sluse44d_oa
sluse44d_pm
5.3
Recommended Operating Conditions
over operating free-air temperature range. All voltages are with reference to GND (unless otherwise noted)
MIN
NOM
MAX
UNIT
Supply voltage, VDD
4.5
12
26
V
Input voltage, INA, INB, ENA, ENB
–10
26
V
Output Voltage, OUTA, OUTB
0
VDD
V
Operating junction temperature, T
J
–40
150
°C