SLUSAW0B March 2012 – December 2023 UCC28070A
PRODUCTION DATA
The main specifications for the PFC MOSFETs are:
The losses in the device are calculated by Equation 45 and Equation 46. These calculations are approximations because the losses are dependent on parameters which are not well controlled. For example, the RDS(on) of a MOSFET may increase by a factor of 2 from 25°C to 125°C. Therefore several iterations may be needed to choose an optimum device for an application different than the one discussed here.
Each phase carries half the load power so the conduction losses are estimated by:
The switching losses in each MOSFET are estimated by:
The total losses in each MOSFET are then: