SLUSEP2 December 2021 UCC28781
PRODUCTION DATA
The UCC28781 controller operates with cycle-by-cycle primary-peak current control. The normal operating range of the CS pin is between VCST(MIN) and VCST(MAX). If the CS-pin voltage exceeds the 1.2-V over-current level, any time after the internal leading edge blanking time (tCSLEB) and before the end of the transformer demagnetization, for three consecutive PWML cycles, the device stops switching, RUN pin goes low, and the fault response is triggered. Similar to OVP, OPP, and SCP, only the UVLO-cycle of VDD is active, there are no test PWML pulses at all. After the 1.5-s time-out is completed and VVDD reaches the next VDD(OFF), a normal start sequence begins.