JAJSNR5A june   2022  – july 2023 ADC12QJ1600-SP

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. 概要 (続き)
  6. Revision History
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Electrical Characteristics: DC Specifications
    6. 7.6  Electrical Characteristics: Power Consumption
    7. 7.7  Electrical Characteristics: AC Specifications
    8. 7.8  Switching Characteristics
    9. 7.9  Timing Requirements
    10. 7.10 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Analog Input
        1. 8.3.1.1 Analog Input Protection
        2. 8.3.1.2 Full-Scale Voltage (VFS) Adjustment
        3. 8.3.1.3 Analog Input Offset Adjust
        4. 8.3.1.4 ADC Core
          1. 8.3.1.4.1 ADC Theory of Operation
          2. 8.3.1.4.2 ADC Core Calibration
          3. 8.3.1.4.3 Analog Reference Voltage
          4. 8.3.1.4.4 ADC Over-range Detection
          5. 8.3.1.4.5 Code Error Rate (CER)
      2. 8.3.2 Temperature Monitoring Diode
      3. 8.3.3 Timestamp
      4. 8.3.4 Clocking
        1. 8.3.4.1 Converter PLL (C-PLL) for Sampling Clock Generation
        2. 8.3.4.2 LVDS Clock Outputs (PLLREFO±, TRIGOUT±)
        3. 8.3.4.3 Optional CMOS Clock Outputs (ORC, ORD)
        4. 8.3.4.4 SYSREF for JESD204C Subclass-1 Deterministic Latency
          1. 8.3.4.4.1 SYSREF Capture for Multi-Device Synchronization and Deterministic Latency
          2. 8.3.4.4.2 SYSREF Position Detector and Sampling Position Selection (SYSREF Windowing)
      5. 8.3.5 JESD204C Interface
        1. 8.3.5.1  Transport Layer
        2. 8.3.5.2  Scrambler
        3. 8.3.5.3  Link Layer
        4. 8.3.5.4  8B or 10B Link Layer
          1. 8.3.5.4.1 Data Encoding (8B or 10B)
          2. 8.3.5.4.2 Multiiframes and the Local Multiframe Clock (LMFC)
          3. 8.3.5.4.3 Code Group Synchronization (CGS)
          4. 8.3.5.4.4 Initial Lane Alignment Sequence (ILAS)
          5. 8.3.5.4.5 Frame and Multiframe Monitoring
        5. 8.3.5.5  64B or 66B Link Layer
          1. 8.3.5.5.1 64B or 66B Encoding
          2. 8.3.5.5.2 Multiblocks, Extended Multiblocks and the Local Extended Multiblock Clock (LEMC)
            1. 8.3.5.5.2.1 Block, Multiblock and Extended Multiblock Alignment using Sync Header
              1. 8.3.5.5.2.1.1 Cyclic Redundancy Check (CRC) Mode
              2. 8.3.5.5.2.1.2 Forward Error Correction (FEC) Mode
          3. 8.3.5.5.3 Initial Lane Alignment
          4. 8.3.5.5.4 Block, Multiblock and Extended Multiblock Alignment Monitoring
        6. 8.3.5.6  Physical Layer
          1. 8.3.5.6.1 SerDes Pre-Emphasis
        7. 8.3.5.7  JESD204C Enable
        8. 8.3.5.8  Multi-Device Synchronization and Deterministic Latency
        9. 8.3.5.9  Operation in Subclass 0 Systems
        10. 8.3.5.10 Alarm Monitoring
          1. 8.3.5.10.1 Clock Upset Detection
          2. 8.3.5.10.2 FIFO Upset Detection
    4. 8.4 Device Functional Modes
      1. 8.4.1 Low Power Mode and High Performance Mode
      2. 8.4.2 JESD204C Modes
        1. 8.4.2.1 JESD204C Transport Layer Data Formats
        2. 8.4.2.2 64B or 66B Sync Header Stream Configuration
        3. 8.4.2.3 Redundant Data Mode (Alternate Lanes)
      3. 8.4.3 Power-Down Modes
      4. 8.4.4 Test Modes
        1. 8.4.4.1 Serializer Test-Mode Details
        2. 8.4.4.2 PRBS Test Modes
        3. 8.4.4.3 Clock Pattern Mode
        4. 8.4.4.4 Ramp Test Mode
        5. 8.4.4.5 Short and Long Transport Test Mode
          1. 8.4.4.5.1 Short Transport Test Pattern
        6. 8.4.4.6 D21.5 Test Mode
        7. 8.4.4.7 K28.5 Test Mode
        8. 8.4.4.8 Repeated ILA Test Mode
        9. 8.4.4.9 Modified RPAT Test Mode
      5. 8.4.5 Calibration Modes and Trimming
        1. 8.4.5.1 Foreground Calibration Mode
        2. 8.4.5.2 Background Calibration Mode
        3. 8.4.5.3 Low-Power Background Calibration (LPBG) Mode
      6. 8.4.6 Offset Calibration
      7. 8.4.7 Trimming
    5. 8.5 Programming
      1. 8.5.1 Using the Serial Interface
      2. 8.5.2 SCS
      3. 8.5.3 SCLK
      4. 8.5.4 SDI
      5. 8.5.5 SDO
      6. 8.5.6 Streaming Mode
      7. 8.5.7 SPI_Register_Map Registers
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Applications
      1. 9.2.1 Light Detection and Ranging (LiDAR) Digitizer
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Analog Front-End Requirements
          2. 9.2.1.2.2 Calculating Clock and SerDes Frequencies
        3. 9.2.1.3 Application Curves
    3. 9.3 Initialization Set Up
    4. 9.4 Power Supply Recommendations
      1. 9.4.1 Power Sequencing
    5. 9.5 Layout
      1. 9.5.1 Layout Guidelines
      2. 9.5.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Device Support
    2. 10.2 ドキュメントの更新通知を受け取る方法
    3. 10.3 サポート・リソース
    4. 10.4 Trademarks
    5. 10.5 静電気放電に関する注意事項
    6. 10.6 用語集
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • ALR|144
サーマルパッド・メカニカル・データ
発注情報

Timing Requirements

MIN NOM MAX UNIT
ADC SAMPLING CLOCK
fS ADC core sampling clock frequency High Performance Mode 500(1) 1600(1) MHz
Low Power Mode 1000(1)
ADC core minimum sampling clock frequency Low Power Mode 500(1)
tS ADC core sampling clock period High Performance Mode 625(1) 2000(1) ps
Low Power Mode 1000(1) ps
ADC core maximum sampling clock period Low Power Mode 2000(1) ps
CLOCK INPUTS (CLK+, CLK–, SE_CLK)
fCLK CLK± input frequency PLL Disabled 500 1600 MHz
PLL Enabled, PLLREF_SE = 0 50 500
fSE_CLK SE_CLK input frequency PLL Enabled, PLLREF_SE = 1 50 500 MHz
DC(CLKMIN) Minimum Input clock duty cycle (CLK± and SE_CLK) Input clock duty cycle (CLK± and SE_CLK) 40%
DC(CLKMAX) Maximum Input clock duty cycle (CLK± and SE_CLK) 60%
PHASE-LOCKED LOOP (PLL) AND VOLTAGE-CONTROLLED OSCILLATOR (VCO)
fPLLPFD PLL phase-frequency detector (PFD) frequency PLL Enabled 50 500 MHz
fVCO Closed-loop voltage-controlled oscillator (VCO) frequency PLL Enabled 7200 8200 MHz
SYSREF (SYSREF+, SYSREF–)
tINV(SYSREF) Width of invalid SYSREF capture region of CLK± period, indicating setup or hold time violation, as measured by SYSREF_POS status register(2) 250 ps
tINV(TEMP) Drift of invalid SYSREF capture region over temperature, positive number indicates a shift toward MSB of SYSREF_POS register 0.05 ps/°C
tINV(VA11) Drift of invalid SYSREF capture region over VA11 supply voltage, positive number indicates a shift toward MSB of SYSREF_POS register -0.17 ps/mV
tSTEP(SP) Delay of SYSREF_POS LSB SYSREF_ZOOM = 0 125 ps
SYSREF_ZOOM = 1 69
DC(SYSREF) SYSREF duty cycle (asserted) when using a periodic SYSREF signal 50% 55%
t(PH_SYS) Minimum SYSREF± assertion duration after SYSREF± rising edge event 4 ns
JESD204C SYNC TIMING (SYNCSE)
SERIAL PROGRAMMING INTERFACE (SCLK, SDI, SCS)
fCLK(SCLK) Serial clock frequency 0 15.625 MHz
t(PH) Serial clock high value pulse duration 32 ns
t(PL) Serial clock low value pulse duration 32 ns
tSU(SCS) Setup time from SCS to rising edge of SCLK 25 ns
tH(SCS) Hold time from rising edge of SCLK to SCS 3 ns
tSU(SDI) Setup time from SDI to rising edge of SCLK 25 ns
tH(SDI) Hold time from rising edge of SCLK to SDI 3 ns
Unless functionally limited to a smaller range in the tables Operating Modes for Quad Channel Device based on programmed JMODE.
Use SYSREF_POS to select an optimal SYSREF_SEL value for the SYSREF capture, see the section SYSREF Windowing for more information on SYSREF windowing. The invalid region, specified by tINV(SYSREF), indicates the portion of the CLK± period(tCLK), as measured by SYSREF_SEL, that may result in a setup and hold violation. Verify that the timing skew between SYSREF± and CLK± over system operating conditions from the nominal conditions (that used to find optimal SYSREF_SEL) does not result in the invalid region occurring at the selected SYSREF_SEL position in SYSREF_POS, otherwise a temperature dependent SYSREF_SEL selection may be needed to track the skew between CLK± and SYSREF±.