Typical values at TA = 25 °C, ADC sampling rate = 25 MSPS, AIN = –1 dBFS differential input, AVDD = IOVDD = 1.8 V, external 1.6 V voltage reference, unless otherwise noted.
SNR = 82.1 dBFS, SFDR = 87 dBc, Non HD23 = 102 dBFS |
Figure 6-18 Single Tone FFT at FIN = 1 MHzSNR = 82.5 dBFS, SFDR = 82 dBc, Non HD23 = 101 dBFS |
Figure 6-20 Single Tone FFT at FIN = 5 MHz, AIN = -20 dBFSSNR = 81.7 dBFS, SFDR = 83 dBc, Non HD23 = 98 dBFS |
Figure 6-22 Single Tone FFT at FIN = 20 MHzAIN = -7 dBFS/tone, IMD3 = 84 dBc |
Figure 6-24 Two Tone FFT at FIN = 3/4 MHzAIN = -20 dBFS/tone, IMD3 = 88 dBc |
Figure 6-26 Two Tone FFT at FIN = 10/12 MHzFigure 6-28 ENOB vs Input Frequency Figure 6-30 AC Performance vs Sampling Rate Figure 6-32 AC Performance vs AVDD Figure 6-36 DC Offset Histogram Figure 6-38 IIOVDD Current vs Decimation SNR = 82.0 dBFS, SFDR = 92 dBc, Non HD23 = 101 dBFS |
Figure 6-19 Single Tone FFT at FIN = 5 MHzSNR = 81.9 dBFS, SFDR = 85 dBc, Non HD23 = 101 dBFS |
Figure 6-21 Single Tone FFT at FIN = 10 MHzSNR = 78.8 dBFS, SFDR = 87 dBc, Non HD23 = 98 dBFS |
Figure 6-23 Single Tone FFT at FIN = 40 MHzAIN = -7 dBFS/tone, IMD3 = 87 dBc |
Figure 6-25 Two Tone FFT at FIN = 10/12 MHzFigure 6-27 AC Performance vs Input Frequency Figure 6-29 AC Performance vs Input Amplitude Figure 6-31 AC Performance vs Clock Amplitude Figure 6-33 AC Performance vs VCM vs Temperature FIN = 1.1 MHz, DDC Bypass |
Figure 6-37 Current vs Sampling RateFIN = 1.1 MHz, Complex Decimation by 32 |
Figure 6-39 IIOVDD Current vs Interface