JAJSIN4D October 2003 – February 2020 ADS1204
PRODUCTION DATA.
A differential input signal of 0 V will ideally produce a stream of ones and zeros that are high 50% of the time and low 50% of the time. A differential input of 2 V produces a stream of ones and zeros that are high 80% of the time. A differential input of –2 V produces a stream of ones and zeros that are high 20% of the time. The input voltage versus the output modulator signal is shown in Figure 30.