JAJSHL9A June 2019 – January 2021 ADS125H01
PRODUCTION DATA
The digital filter has two operating modes, as shown in Figure 9-6: sin(x) / x (sinc) mode and finite impulse response (FIR) mode. The sinc mode provides data rates of 2.5 SPS to 40 kSPS, and selectable sinc1, sinc3, and sinc4 filter orders for fDATA ≤ 7.2 kSPS. The FIR filter provides single-cycle settled conversions and simultaneous rejection of 50-Hz and 60-Hz signal interference frequencies with data rates of 2.5 SPS to 20 SPS.