JAJSHV5B June   2017  – August 2019 ADS1287

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     Device Images
      1.      機能ブロック図
  4. 改訂履歴
  5. 概要(続き)
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements
    7. 7.7 Switching Characteristics
    8. 7.8 Typical Characteristics
  8. Parameter Measurement Information
    1. 8.1 Noise Performance
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Analog Input and Multiplexer
      2. 9.3.2 Programmable Gain Amplifier (PGA)
      3. 9.3.3 Modulator
        1. 9.3.3.1 Modulator Overrange
      4. 9.3.4 Voltage Reference Inputs (REFP, REFN)
      5. 9.3.5 Digital Filter
        1. 9.3.5.1 Sinc Filter Stage
        2. 9.3.5.2 FIR Filter Stage
        3. 9.3.5.3 Group Delay and Step Response
          1. 9.3.5.3.1 Linear Phase Response
          2. 9.3.5.3.2 Minimum Phase Response
        4. 9.3.5.4 HPF Stage
      6. 9.3.6 Reset (RESET Pin and Reset Command)
      7. 9.3.7 Master Clock Input (CLK)
    4. 9.4 Device Functional Modes
      1. 9.4.1  Operational Mode
      2. 9.4.2  Chop Mode
      3. 9.4.3  Offset
      4. 9.4.4  Power-Down Mode
      5. 9.4.5  Standby Mode
      6. 9.4.6  Synchronization
        1. 9.4.6.1 Pulse-Sync Mode
        2. 9.4.6.2 Continuous-Sync Mode
      7. 9.4.7  Reading Data
        1. 9.4.7.1 Read-Data-Continuous Mode (RDATAC)
        2. 9.4.7.2 Stop-Read-Data-Continuous-Mode (SDATAC)
      8. 9.4.8  Conversion Data Format
      9. 9.4.9  Offset and Full-Scale Calibration Registers
        1. 9.4.9.1 OFC[2:0] Registers
        2. 9.4.9.2 FSC[2:0] Registers
      10. 9.4.10 Calibration Command
        1. 9.4.10.1 OFSCAL Command
        2. 9.4.10.2 GANCAL Command
      11. 9.4.11 User Calibration
    5. 9.5 Programming
      1. 9.5.1 Serial Interface
        1. 9.5.1.1 Chip Select (CS)
        2. 9.5.1.2 Serial Clock (SCLK)
        3. 9.5.1.3 Data Input (DIN)
        4. 9.5.1.4 Data Output (DOUT)
        5. 9.5.1.5 Serial Interface Timeout
        6. 9.5.1.6 Data Ready (DRDY)
      2. 9.5.2 Commands
        1. 9.5.2.1  WAKEUP: Wake Up Command
        2. 9.5.2.2  STANDBY: Standby Mode Command
        3. 9.5.2.3  SYNC: Synchronize ADC Conversions
        4. 9.5.2.4  RESET: Reset Command
        5. 9.5.2.5  RDATAC: Read Data Continuous Mode Command
        6. 9.5.2.6  SDATAC: Stop Read Data Continuous Mode Command
        7. 9.5.2.7  RDATA: Read Data Command
        8. 9.5.2.8  RREG: Read Register Data Command
        9. 9.5.2.9  WREG: Write Register Data Command
        10. 9.5.2.10 OFSCAL: Offset Calibration Command
        11. 9.5.2.11 GANCAL: Gain Calibration Command
    6. 9.6 Register Map
      1. 9.6.1 Register Descriptions
        1. 9.6.1.1 ID/CFG: ID, Configuration Register (address = 00h) [reset = x0h]
          1. Table 22. ID/CFG Register Field Descriptions
        2. 9.6.1.2 CONFIG0: Configuration Register 0 (address = 01h) [reset = 52h]
          1. Table 23. CONFIG0 Register Field Descriptions
        3. 9.6.1.3 CONFIG1: Configuration Register 1 (address = 02h) [reset = 08h]
          1. Table 24. CONFIG1 Register Field Descriptions
        4. 9.6.1.4 High-Pass Filter Corner Frequency (HPFx) Registers (address = 03h, 04h) [reset = 32h, 03h]
          1. Table 25. HPF0, HPF1 Registers Field Description
        5. 9.6.1.5 Offset Calibration (OFCx) Registers (address = 05h, 06h, 07h) [reset = 00h, 00h, 00h]
          1. Table 26. OFC0, OFC1, OFC2 Registers Field Description
        6. 9.6.1.6 Full-Scale Calibration (FSCx) Registers (address = 08h, 09h, 0Ah) [reset = 00h, 00h, 40h]
          1. Table 27. FSC0, FSC1, FSC2 Registers Field Description
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Applications
      1. 10.2.1 Geophone Application
      2. 10.2.2 Digital Interface
    3. 10.3 Initialization Set Up
  11. 11Power Supply Recommendations
    1. 11.1 Analog Power Supplies
    2. 11.2 Digital Power Supply
    3. 11.3 Power-Supply Sequence
  12. 12Layout
    1. 12.1 Layout Guidelines
  13. 13デバイスおよびドキュメントのサポート
    1. 13.1 ドキュメントの更新通知を受け取る方法
    2. 13.2 コミュニティ・リソース
    3. 13.3 商標
    4. 13.4 静電気放電に関する注意事項
    5. 13.5 Glossary
  14. 14メカニカル、パッケージ、および注文情報

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • RHF|24
サーマルパッド・メカニカル・データ
発注情報

Commands

The commands listed in Table 19 control ADC operation. Most commands are stand-alone (that is, one byte in length); the register read and write command lengths are two bytes, plus additional data bytes that represent the actual register data.

Table 19. Command Descriptions

COMMAND TYPE DESCRIPTION 1ST COMMAND BYTE(1)(2) 2ND COMMAND BYTE(3)
WAKEUP Control Wake-up from standby mode 0000 000X (00h or 01h)
STANDBY Control Enter standby mode 0000 001X (02h or 03h)
SYNC Control Synchronize ADC conversions 0000 010X (04h or 5h)
RESET Control Reset the ADC 0000 011X (06h or 07h)
RDATAC Control Read data continuous mode 0001 0000 (10h)
SDATAC Control Stop read data continuous mode 0001 0001 (11h)
RDATA Data Read data by command(4) 0001 0010 (12h)
RREG Register Read nnnnn registers at address rrrrr(4) 001r rrrr (20h + 000r rrrr) 000n nnnn (00h + n nnnn)
WREG Register Write nnnnn registers at address rrrrr 010r rrrr (40h + 000r rrrr) 000n nnnn (00h + n nnnn)
OFSCAL Calibration Offset calibration 0110 0000 (60h)
GANCAL Calibration Gain calibration 0110 0001 (61h)
X = don't care.
rrrrr = starting address for register read and write commands.
nnnnn = number of registers to be read from or written to – 1. For example, to read from or write to three registers, set nnnnn = 2 (00010).
Required to cancel read-data-continuous mode before sending a command.

CS must remain low for the duration of the command-byte sequence. Provide a 24 / fCLK delay between commands, between bytes within a command, and from the last byte of a command prior to returning CS high. The required delay starts from the last SCLK rising edge of the preceding byte to the first SCLK rising edge of the following byte; see Figure 2. The delay between data bytes is not necessary when reading conversion data.