B. The input pulse is supplied
by a generator having the following characteristics: ZO = 50 Ω,
PRR = 10 MHz, tr and tf (10% to 90%) ≤ 2 ns, 50% duty
cycle.
C. To test the active-low enable
G, ground G and apply an inverted waveform
G.
Figure 7-1 tPLH and tPHL Test Circuit and Voltage
Waveforms
A. CL includes probe
and jig capacitance.
B. The input pulse is supplied
by a generator having the following characteristics: ZO = 50 Ω,
PRR = 10 MHz, tr and tf (10% to 90%) ≤ 2 ns, 50% duty
cycle.
C. To test the active-low enable
G, ground G and apply an inverted waveform
G.
Figure 7-2 tPZH and tPHZ Test Circuit and Voltage
Waveforms
A. CL includes probe
and jig capacitance.
B. The input pulse is supplied
by a generator having the following characteristics: ZO = 50 Ω,
PRR = 10 MHz, tr and tf (10% to 90%) ≤ 2 ns, 50% duty
cycle.
C. To test the active-low enable
G, ground G and apply an inverted waveform
G.
Figure 7-3 tPZL and tPLZ Test Circuit and Voltage
Waveforms