SBASB13
December 2024
AMC0311S
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Device Comparison Table
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information (D Package)
6.5
Thermal Information (DWV Package)
6.6
Power Ratings
6.7
Insulation Specifications (Basic Isolation)
6.8
Insulation Specifications (Reinforced Isolation)
6.9
Safety-Related Certifications (Basic Isolation)
6.10
Safety-Related Certifications (Reinforced Isolation)
6.11
Safety Limiting Values (D Package)
6.12
Safety Limiting Values (DWV Package)
6.13
Electrical Characteristics
6.14
Switching Characteristics
6.15
Timing Diagram
6.16
Insulation Characteristics Curves
6.17
Typical Characteristics
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Analog Input
7.3.2
Isolation Channel Signal Transmission
7.3.3
Analog Output
7.4
Reference Input
7.5
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.2.1
Input Filter Design
8.2.2.2
Connecting the REFIN pin
8.2.3
Application Curve
8.3
Best Design Practices
8.4
Power Supply Recommendations
8.5
Layout
8.5.1
Layout Guidelines
8.5.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Revision History
11
Mechanical, Packaging, and Orderable Information
パッケージ・オプション
メカニカル・データ(パッケージ|ピン)
DWV|8
MPDS382B
サーマルパッド・メカニカル・データ
発注情報
sbasb13_oa
sbasb13_pm
6.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±2000
V
Charged-device model (CDM), per per ANSI/ESDA/JEDEC JS-002
(2)
±1000
(1)
JEDEC document JEP155 states that 500V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250V CDM allows safe manufacturing with a standard ESD control process.