JAJSND8C September 2021 – January 2023 BQ25180
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
The BQ25180 has four main modes of operation: Battery Mode, Ship Mode, Charge/Adapter Mode when a supply is connected to IN, and Shutdown mode. The table below summarizes the functions that are active for each operation mode.
FUNCTION |
CHARGE/ADAPTER MODE |
BATTERY MODE |
SHIP MODE |
SHUTDOWN MODE |
---|---|---|---|---|
Input overvoltage |
Yes |
Yes |
No |
No |
Input undervoltage |
Yes |
Yes |
Yes |
Yes |
Battery overcurrent |
Yes, if enabled |
Yes |
Yes, if enabled |
No |
Battery undervoltage |
Yes |
Yes |
No |
No |
Input DPM |
Yes, if enabled |
No |
No |
No |
Dynamic power path management |
Yes, if enabled |
No |
No |
No |
BATFET |
Yes |
Yes |
No |
No |
TS measurement |
Yes |
No |
No |
No |
Battery charging |
Yes, if enabled |
No |
No |
No |
ILIM |
Yes (Register Value) |
No |
No |
No |
Pushbutton input |
Yes |
Yes, if enabled |
Yes |
No |
INT output |
Yes |
Yes |
No |
No |
I2C |
Yes |
Yes |
No |
No |