JAJSKU9B December 2022 – February 2024 BQ25628 , BQ25629
PRODUCTION DATA
During boost OTG mode, BQ25628 converter monitors PMID for undervoltage. If the PMID voltage falls below VOTG_UVP, the converter stops and enters hiccup mode.
If the boost converter cannot recover from hiccup mode, EN_OTG bit is cleared and the device exits boost mode. The host may attempt to restart boost OTG mode by setting EN_OTG = 1.