JAJSFQ9C june 2018 – may 2023 BQ25713 , BQ25713B
PRODUCTION DATA
Usually adapter can supply current higher than DC rating for a few milliseconds to tens of milliseconds. The charger employs two-level input current limit, or peak power mode, to fully utilize the overloading capability and minimize battery discharge during CPU turbo mode. Peak power mode is enabled in REG0x33[5:4]. The DC current limit, or ILIM1, is the same as adapter DC current, set in REG0x0F/0E(). The overloading current, or ILIM2, is set in REG0x37[7:3], as a percentage of ILIM1.
When the charger detects input current surge and battery discharge due to load transient (both the adapter and battery support the system together), or when the charger detects the system voltage starts to drop due to load transient (only the adapter supports the system), the charger will first apply ILIM2 for TOVLD in REG0x33[7:6], and then ILIM1 for up to TMAX – TOVLD time. TMAX is programmed in REG0x33[1:0]. After TMAX, if the load is still high, another peak power cycle starts. Charging is disabled during TMAX,; once TMAX, expires, charging continues. If TOVLD is programmed to be equal to TMAX, then peak power mode is always on.