SLUSEK7 September 2024 BQ25773
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
The device supports USB OTG operation to deliver power from the battery to other portable devices through USB port. The OTG output voltage is set in OTG_VOLTAGE() register with 20 mV LSB range from 3.0 V to 5 V. The OTG output current limit is set in OTG_CURRENT() register with 50 mA LSB range from 0 A to 3 A under 10 mΩ input current sensing. Status bit IN_IIN_DPM is used to report output current is under OTG_CURRENT() regulation; status bit IN_VINDPM is used to report output voltage is under OTG_VOLTAGE() regulation. Both OTG voltage and OTG current are qualified for USB-PD programed power supply (PPS) specification in terms of resolution and accuracy. The OTG operation can be enabled if the conditions are valid:
EN_OTG pin is used as multi-function to enable OTG, VAP and FRS mode. In order to enable OTG mode correctly, please refer to Table 7-5 case 6. OTG_VAP_MODE=1b should be configured before EN_OTG pin pulled high. After EN_OTG pin is pulled up, it is not recommended to change OTG_VAP_MODE bit value.