JAJSLN6C May 2012 – May 2021 BQ34Z100
PRODUCTION DATA
For proper BQ34Z100 operation, the battery per cell charging voltage must be specified by the user . The default value for this variable is Charging Voltage = 4200 mV. This parameter should be set to the recommended charging voltage for the entire battery stack .
The device detects charge termination when (1) during two consecutive periods of Current Taper Window, the AverageCurrent() is < Taper Current and (2) during the same periods, the accumulated change in capacity > 0.25 mAh /Taper Current Window and (3) Voltage() > Charging Voltage - Charging Taper Voltage. When this occurs, the [CHG] bit of Flags() is cleared. Also, if the [RMFCC] bit of Pack Configuration is set, and RemainingCapacity() is set equal to FullChargeCapacity().