JAJSSG6 December   2023 BQ76972

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Device Comparison Table
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information BQ76952
    5. 6.5  Supply Current
    6. 6.6  Digital I/O
    7. 6.7  LD Pin
    8. 6.8  Precharge (PCHG) and Predischarge (PDSG) FET Drive
    9. 6.9  FUSE Pin Functionality
    10. 6.10 REG18 LDO
    11. 6.11 REG0 Pre-regulator
    12. 6.12 REG1 LDO
    13. 6.13 REG2 LDO
    14. 6.14 Voltage References
    15. 6.15 Coulomb Counter
    16. 6.16 Coulomb Counter Digital Filter (CC1)
    17. 6.17 Current Measurement Digital Filter (CC2)
    18. 6.18 Current Wake Detector
    19. 6.19 Analog-to-Digital Converter
    20. 6.20 Cell Voltage Measurement Accuracy
    21. 6.21 Cell Balancing
    22. 6.22 Cell Open Wire Detector
    23. 6.23 Internal Temperature Sensor
    24. 6.24 Thermistor Measurement
    25. 6.25 Internal Oscillators
    26. 6.26 High-side NFET Drivers
    27. 6.27 Comparator-Based Protection Subsystem
    28. 6.28 Timing Requirements - I2C Interface, 100kHz Mode
    29. 6.29 Timing Requirements - I2C Interface, 400kHz Mode
    30. 6.30 Timing Requirements - HDQ Interface
    31. 6.31 Timing Requirements - SPI Interface
    32. 6.32 Interface Timing Diagrams
    33. 6.33 Typical Characteristics
  8. Detailed Description
    1. 7.1  Overview
    2. 7.2  Functional Block Diagram
    3. 7.3  BQ76972 Device Versions
    4. 7.4  Diagnostics
    5. 7.5  Device Configuration
      1. 7.5.1 Commands and Subcommands
      2. 7.5.2 Configuration Using OTP or Registers
      3. 7.5.3 Device Security
      4. 7.5.4 Scratchpad Memory
    6. 7.6  Measurement Subsystem
      1. 7.6.1  Voltage Measurement
        1. 7.6.1.1 Voltage Measurement Schedule
        2. 7.6.1.2 Usage of VC Pins for Cells Versus Interconnect
        3. 7.6.1.3 Cell 1 Voltage Validation During SLEEP Mode
      2. 7.6.2  General Purpose ADCIN Functionality
      3. 7.6.3  Coulomb Counter and Digital Filters
      4. 7.6.4  Synchronized Voltage and Current Measurement
      5. 7.6.5  Internal Temperature Measurement
      6. 7.6.6  Thermistor Temperature Measurement
      7. 7.6.7  Factory Trim of Voltage ADC
      8. 7.6.8  Cell Voltage Measurement Accuracy
        1. 7.6.8.1 Fixed Offset Adjustment
        2. 7.6.8.2 Cell Offset Calibration
      9. 7.6.9  Voltage Calibration (ADC Measurements)
      10. 7.6.10 Voltage Calibration (COV and CUV Protections)
      11. 7.6.11 Current Calibration
      12. 7.6.12 Temperature Calibration
    7. 7.7  Primary and Secondary Protection Subsystems
      1. 7.7.1 Protections Overview
      2. 7.7.2 Primary Protections
      3. 7.7.3 Secondary Protections
      4. 7.7.4 High-Side NFET Drivers
      5. 7.7.5 Protection FETs Configuration and Control
        1. 7.7.5.1 FET Configuration
        2. 7.7.5.2 PRECHARGE and PREDISCHARGE Modes
      6. 7.7.6 Load Detect Functionality
    8. 7.8  Device Hardware Features
      1. 7.8.1  Voltage References
      2. 7.8.2  ADC Multiplexer
      3. 7.8.3  LDOs
        1. 7.8.3.1 Preregulator Control
        2. 7.8.3.2 REG1 and REG2 LDO Controls
      4. 7.8.4  Standalone Versus Host Interface
      5. 7.8.5  Multifunction Pin Controls
      6. 7.8.6  RST_SHUT Pin Operation
      7. 7.8.7  CFETOFF, DFETOFF, and BOTHOFF Pin Functionality
      8. 7.8.8  ALERT Pin Operation
      9. 7.8.9  DDSG and DCHG Pin Operation
      10. 7.8.10 Fuse Drive
      11. 7.8.11 Cell Open Wire
      12. 7.8.12 Low Frequency Oscillator
      13. 7.8.13 High Frequency Oscillator
    9. 7.9  Device Functional Modes
      1. 7.9.1 Overview
      2. 7.9.2 NORMAL Mode
      3. 7.9.3 SLEEP Mode
      4. 7.9.4 DEEPSLEEP Mode
      5. 7.9.5 SHUTDOWN Mode
      6. 7.9.6 CONFIG_UPDATE Mode
    10. 7.10 Serial Communications Interface
      1. 7.10.1 Serial Communications Overview
      2. 7.10.2 I2C Communications
      3. 7.10.3 SPI Communications
        1. 7.10.3.1 SPI Protocol
      4. 7.10.4 HDQ Communications
    11. 7.11 Cell Balancing
      1. 7.11.1 Cell Balancing Overview
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Design Requirements (Example)
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Performance Plot
      4. 8.2.4 Calibration Process
    3. 8.3 Random Cell Connection Support
    4. 8.4 Startup Timing
    5. 8.5 FET Driver Turn-Off
    6. 8.6 Unused Pins
    7. 8.7 Power Supply Requirements
    8. 8.8 Layout
      1. 8.8.1 Layout Guidelines
      2. 8.8.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Fixed Offset Adjustment

To obtain finalized cell measurement values, the host processor performs a fixed offset adjustment by subtracting fixed per-cell offset values from the reported cell measurement results.

The per-cell offset values are the same for all devices and do not require measurement of each device on the customer production line.

Two sets of offset adjustment values are provided as follows:

  • One set optimized for LFP cells, with cell voltages ranging from 2 V to 3.7 V
  • A second set optimized for Li-ion cells, with cell voltages ranging from 2 V to 4.5 V

The two sets of optimized offset values are described below.

Table 7-1 Fixed Offset Adjustment Values Optimized for LFP Cells
OFFSET VALUE CELL 1 OFFSET CELL 2 OFFSET CELL 3 OFFSET CELL 4 OFFSET CELL 5 OFFSET CELL 6 OFFSET CELL 7 OFFSET CELL 8 OFFSET
OFFSET (mV) –0.6 –0.8 –0.8 –0.8 –0.5 –0.6 –0.6 –0.6
OFFSET VALUE CELL 9 OFFSET CELL 10 OFFSET CELL 11 OFFSET CELL 12 OFFSET CELL 13 OFFSET CELL 14 OFFSET CELL 15 OFFSET CELL 16 OFFSET
OFFSET (mV) –0.3 –0.4 –0.1 –0.1 –1.3 –1.1 –1.2 –0.7
Table 7-2 Fixed Offset Adjustment Values Optimized for Li-ion Cells
OFFSET VALUE CELL 1 OFFSET CELL 2 OFFSET CELL 3 OFFSET CELL 4 OFFSET CELL 5 OFFSET CELL 6 OFFSET CELL 7 OFFSET CELL 8 OFFSET
OFFSET (mV) –0.7 –1.0 –0.9 –1.0 –0.6 –0.7 –0.8 –0.9
OFFSET VALUE CELL 9 OFFSET CELL 10 OFFSET CELL 11 OFFSET CELL 12 OFFSET CELL 13 OFFSET CELL 14 OFFSET CELL 15 OFFSET CELL 16 OFFSET
OFFSET (mV) 0.2 0.0 –0.2 –0.4 1.1 0.8 0.7 0.1

During operation, the cell measurements are read from the BQ76972 as Cell 1 Voltage(), Cell 2 Voltage(), and so on. The host then calculates adjusted values for each cell voltage:

  • Final Cell 1 Voltage = Cell 1 Voltage()Cell 1 Offset
  • Final Cell 2 Voltage = Cell 2 Voltage()Cell 2 Offset
  • and so forth
All devices use the same 16 values for Cell 1 Offset, Cell 2 Offset, and so on.