JAJSIJ8J November   1998  – August 2024 CD4066B

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • D|14
  • PW|14
  • NS|14
  • N|14
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

Over operating free-air temperature range, VSUPPLY = ±5V, and RL = 100 Ω, (unless otherwise noted)(1)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
SIGNAL INPUTS (VIS) AND OUTPUTS (VOS)
VOS Switch output voltage VDD = 5V
Vis = 0V
0.4 V
VDD = 5V
Vis = 5V
4.6 V
VDD = 10V
Vis = 0V
0.5 V
VDD = 10V
Vis = 10V
9.5 V
VDD = 15V
Vis = 0V
1.5 V
VDD = 15V
Vis = 15V
13.5 V
ΔRON On-state resistance difference between any two switches RL = 10kΩ, VC = VDD VDD = 5V 15 Ω
On-state resistance difference between any two switches On-state resistance difference between any two switches VDD = 10V 10
On-state resistance difference between any two switches On-state resistance difference between any two switches VDD = 15V 5
VIHC Control input, high voltage See Figure 7 VDD = 5V 3.5 V
VDD = 10V 7 V
VDD = 15V 11 V
Maximum control input repetition rate VIN = VDD, CL = 50pF, RL = 1kΩ
VC = 10V (square wave centered on 5V), tr , tf = 20ns, Vos = 1/2Vos at 1kHz
VDD = 5V 6 MHz
VDD = 10V 9
VDD = 15V 9.5
CIN Input Capacitance 5 7.5 pF
IIS Switch input current VDD = 5V
Vis = 0V
TA = –55°C 0.64 mA
TA = –40°C 0.61
TA = 25°C 0.51
TA = 85°C 0.42
TA = 125°C 0.36
VDD = 5V
Vis = 5V
TA = –55°C -0.64 mA
TA = –40°C -0.61
TA = 25°C -0.51
TA = 85°C -0.42
TA = 125°C -0.36
VDD = 10V
Vis = 0V
TA = –55°C 1.6 mA
TA = –40°C 1.5
TA = 25°C 1.3
TA = 85°C 1.1
TA = 125°C 0.9
VDD = 10V
Vis = 10V
TA = –55°C -1.6 mA
TA = –40°C -1.5
TA = 25°C -1.3
TA = 85°C -1.1
TA = 125°C -0.9
VDD = 15V
Vis = 0V
TA = –55°C 4.2 mA
TA = –40°C 4
TA = 25°C 3.4
TA = 85°C 2.8
TA = 125°C 2.4
VDD = 15V
Vis = 15V
TA = –55°C -4.2 mA
TA = –40°C -4
TA = 25°C -3.4
TA = 85°C -2.8
TA = 125°C -2.4
IDD

Quiescent Device Current
All switches OFF
Vis = 0 to 5V
VDD = 5V
TA = –55°C 5 µA
TA = –40°C 5
TA = 25°C 4 6
TA = 85°C 7
TA = 125°C 7.5
Vis = 0 to 10V
VDD = 10V
TA = –55°C 6
TA = –40°C 6
TA = 25°C 5 7
TA = 85°C 8
TA = 125°C 9
Vis = 0 to 15V
VDD = 15V
TA = –55°C 7
TA = –40°C 7.5
TA = 25°C 5.5 8
TA = 85°C 9
TA = 125°C 10
Vis = 0 to 20V
VDD = 20V
TA = –55°C 8.5
TA = –40°C 8.5
TA = 25°C 6.5 9
TA = 85°C 10
TA = 125°C 11
rON ON Resistance rON Max to (VDD+VSS)/2 ,VC = VDD,RL = 10kΩ returned Vis = VSS to VDD VDD = 5V TA = –55°C 800 Ω
TA = –40°C 850
TA = 25°C 470 1050
TA = 85°C 1200
TA = 125°C 1300
VDD = 10V TA = –55°C 310
TA = –40°C 330
TA = 25°C 180 400
TA = 85°C 500
TA = 125°C 500
VDD = 15V TA = –55°C 200
TA = –40°C 210
TA = 25°C 125 240
TA = 85°C 300
TA = 125°C 320
VILC Control input, low voltage (max) |Iis| < 10 µA, Vis = VSS, VOS = VDD, and Vis = VDD, VOS = VSS VDD = 5V TA = –55°C 1 V
TA = –40°C 1
TA = 25°C 1
TA = 85°C 1
TA = 125°C 1
VDD = 10V TA = –55°C 1
TA = –40°C 1
TA = 25°C 1
TA = 85°C 1
TA = 125°C 1
VDD = 15V TA = –55°C 1
TA = –40°C 1
TA = 25°C 1
TA = 85°C 1
TA = 125°C 1
IIN Input current (max) Vis ≤ VDD, VDD – VSS = 18V, VCC ≤ VDD – VSS VDD = 18V TA = –55°C -0.8 0.8 µA
TA = –40°C -0.8 0.8
TA = 25°C -0.7 ±0.2 0.7
Input current (max) Input current (max) TA = 85°C -0.6 0.6
Input current (max) Input current (max) TA = 125°C -0.55 0.55
Peak-to-Peak voltage symmetrical about (VDD – VEE) / 2.