JAJSHG0N November   1997  – April 2024 CD54HC4051 , CD54HC4052 , CD54HC4053 , CD54HCT4051 , CD74HC4051 , CD74HC4052 , CD74HC4053 , CD74HCT4051 , CD74HCT4052 , CD74HCT4053

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Thermal Information
    4. 5.4  Recommended Operating Conditions
    5. 5.5  Electrical Characteristics: HC Devices
    6. 5.6  Electrical Characteristics: HCT Devices
    7. 5.7  Switching Characteristics, VCC = 5V
    8. 5.8  Switching Characteristics, CL = 50pF
    9. 5.9  Analog Channel Specifications
    10. 5.10 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagrams
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PW|16
  • NS|16
  • N|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Switching Characteristics, CL = 50pF

CL = 50pF, input tr, tf = 6 ns
Parameter VEE (V) VCC (V) Test Conditions MIN NOM MAX UNIT
tPHL, tPLH
Propagation delay, switch in to out
0 2 TA = 25°C HC 60 ns
TA = –40°C to +85°C HC 75
TA = –55°C to +125°C HC 90
0 4.5 TA = 25°C HC, HCT 12
TA = –40°C to +85°C HC, HCT 15
TA = –55°C to +125°C HC, HCT 18
0 6 TA = 25°C HC 10
TA = –40°C to +85°C HC 13
TA = –55°C to +125°C HC 15
-4.5 4.5 TA = 25°C HC, HCT 8
TA = –40°C to +85°C HC, HCT 10
TA = –55°C to +125°C HC, HCT 12
tPHZ, tPLZ
Maximum switch turn OFF delay from S or E to switch output
4051 0 2 TA = 25°C HC 250 ns
TA = –40°C to +85°C HC 340
TA = –55°C to +125°C HC 400
0 4.5 TA = 25°C HC, HCT 50
TA = –40°C to +85°C HC, HCT 56
TA = –55°C to +125°C HC, HCT 68
0 6 TA = 25°C HC 44
TA = –40°C to +85°C HC 50
TA = –55°C to +125°C HC 57
-4.5 4.5 TA = 25°C HC, HCT 44
TA = –40°C to +85°C HC, HCT 50
TA = –55°C to +125°C HC, HCT 55
tPHZ, tPLZ
Maximum switch turn OFF delay from S or E to switch output
4052 0 2 TA = 25°C HC 250 ns
TA = –40°C to +85°C HC 340
TA = –55°C to +125°C HC 400
0 4.5 TA = 25°C HC, HCT 50
TA = –40°C to +85°C HC, HCT 63
TA = –55°C to +125°C HC, HCT 75
0 6 TA = 25°C HC 45
TA = –40°C to +85°C HC 54
TA = –55°C to +125°C HC 65
-4.5 4.5 TA = 25°C HC 45
HCT 45
TA = –40°C to +85°C HC 48
HCT 50
TA = –55°C to +125°C HC 57
HCT 57
tPHZ, tPLZ
Maximum switch turn OFF delay from S or E to switch output
4053 0 2 TA = 25°C HC 250 ns
TA = –40°C to +85°C HC 340
TA = –55°C to +125°C HC 400
0 4.5 TA = 25°C HC 45
HCT 50
TA = –40°C to +85°C HC 53
HCT 53
TA = –55°C to +125°C HC 63
HCT 66
0 6 TA = 25°C HC 45
TA = –40°C to +85°C HC 50
TA = –55°C to +125°C HC 55
-4.5 4.5 TA = 25°C HC 45
HCT 45
TA = –40°C to +85°C HC 50
HCT 50
TA = –55°C to +125°C HC 55
HCT 55
tPZL, tPZH Maximum switch turn ON delay from S or E to switch output 4051 0 2 TA = 25°C HC 325 ns
TA = –40°C to +85°C HC 405
TA = –55°C to +125°C HC 490
0 4.5 TA = 25°C HC 45
HCT 55
TA = –40°C to +85°C HC 56
HCT 69
TA = –55°C to +125°C HC 68
HCT 83
0 6 TA = 25°C HC 38
TA = –40°C to +85°C HC 48
TA = –55°C to +125°C HC 57
-4.5 4.5 TA = 25°C HC 36
HCT 48
TA = –40°C to +85°C HC 40
HCT 55
TA = –55°C to +125°C HC 48
HCT 60
tPZL, tPZH Maximum switch turn ON delay from S or E to switch output 4052 0 2 TA = 25°C HC 325 ns
TA = –40°C to +85°C HC 405
TA = –55°C to +125°C HC 490
0 4.5 TA = 25°C HC 65
HCT 70
TA = –40°C to +85°C HC 81
HCT 68
TA = –55°C to +125°C HC 98
HCT 105
0 6 TA = 25°C HC 55
TA = –40°C to +85°C HC 69
TA = –55°C to +125°C HC 83
-4.5 4.5 TA = 25°C HC 46
HCT 48
TA = –40°C to +85°C HC 58
HCT 60
TA = –55°C to +125°C HC 69
HCT 72
tPZL, tPZH Maximum switch turn ON delay from S or E to switch output 4053 0 2 TA = 25°C HC 325 ns
TA = –40°C to +85°C HC 405
TA = –55°C to +125°C HC 490
0 4.5 TA = 25°C HC 44
HCT 48
TA = –40°C to +85°C HC 55
HCT 60
TA = –55°C to +125°C HC 66
HCT 72
0 6 TA = 25°C HC 37
TA = –40°C to +85°C HC 47
TA = –55°C to +125°C HC 56
-4.5 4.5 TA = 25°C HC 40
HCT 48
TA = –40°C to +85°C HC 45
HCT 55
TA = –55°C to +125°C HC 47
HCT 60
CI Input (control) capacitance TA = 25°C HC, HCT 10 pF
TA = –40°C to +85°C HC, HCT 10
TA = –55°C to +125°C HC, HCT 10