JAJSD34C
April 2017 – April 2018
CSD88599Q5DC
PRODUCTION DATA.
1
特長
2
アプリケーション
3
概要
4
改訂履歴
5
Specifications
5.1
Absolute Maximum Ratings
5.2
Recommended Operating Conditions
5.3
Power Block Performance
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Typical Power Block Device Characteristics
5.7
Typical Power Block MOSFET Characteristics
6
Application and Implementation
6.1
Application Information
6.2
Brushless DC Motor With Trapezoidal Control
6.3
Power Loss Curves
6.4
Safe Operating Area (SOA) Curve
6.5
Normalized Power Loss Curves
6.6
Design Example – Regulate Current to Maintain Safe Operation
6.7
Design Example – Regulate Board and Case Temperature to Maintain Safe Operation
6.7.1
Operating Conditions
6.7.2
Calculating Power Loss
6.7.3
Calculating SOA Adjustments
7
Layout
7.1
Layout Guidelines
7.1.1
Electrical Performance
7.1.2
Thermal Considerations
7.2
Layout Example
8
デバイスおよびドキュメントのサポート
8.1
ドキュメントの更新通知を受け取る方法
8.2
コミュニティ・リソース
8.3
商標
8.4
静電気放電に関する注意事項
8.5
Glossary
9
メカニカル、パッケージ、および注文情報
9.1
Q5DCパッケージの寸法
9.2
推奨ランド・パターン
9.3
推奨ステンシル
パッケージ・オプション
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
メカニカル・データ(パッケージ|ピン)
DMM|22
サーマルパッド・メカニカル・データ
発注情報
jajsd34c_oa
6.7.2
Calculating Power Loss
Power loss at 30 A ≈ 3.4 W (
Figure 1
)
Normalized power loss for switching frequency ≈ 1.19 (
Figure 4
)
Normalized power loss for input voltage ≈ 1.03 (
Figure 5
)
Normalized power loss for duty cycle ≈ 1.12 (
Figure 6
)
Final calculated power loss = 3.4 W × 1.19 × 1.03 × 1.12 ≈ 4.7 W