JAJSES9 February 2018 DAC8771
PRODUCTION DATA.
The DAC8771 contains an ALARM pin. When one or more of following events occur, the ALARM pin is pulled low:
When connecting the ALARM pins of multiple DAC8771 devices together, forming a wired-AND function, the host processor should read the status register of each device to know all the fault conditions that are present.
The ALARM pin continuously monitors the above mentioned conditions and returns to open drain condition if the alarm condition is removed (non-latched behavior - default). For condition (1) mentioned above and Buck-Boost converter used to power the DAC, the ALARM pin if pulled low due to the alarm condition will remain pulled low even after the alarm condition is removed (latched behavior). In this condition the alarm pin can be reset by
Note that if the alarm action bits are programmed to "10" (AC_IOC[1:0], the Buck-Boost converter and the current output amplifier are automatically disabled upon the event of open circuit on current output. In this case, the ALARM automatically resets to the default behavior (non-latched behavior).